En los servidores SPARC S7-2L con una configuración de placa posterior de 12 unidades y solo unidades NVMe, prtdiag muestra nombres NAC incorrectos para las unidades NVMe de las ranuras 3, 4 y 5, como se muestra a continuación.
======================================== IO Devices ======================================= Slot + Bus Name + Model Max Speed Cur Speed Status Type Path /Width /Width ------------------------------------------------------------------------------------------- ... ... /SYS/MB/PCIE_SWITCH1 PCIE nvme-pciexclass,010802 8.0GT/x4 8.0GT/x4 /pci@300/pci@2/pci@0/pci@6/nvme@0 /SYS/MB/PCIE_SWITCH1 PCIE nvme-pciexclass,010802 8.0GT/x4 8.0GT/x4 /pci@300/pci@2/pci@0/pci@7/nvme@0 ... /SYS/MB/CMP1/IOS0 PCIX nvme-pciexclass,010802 8.0GT/x4 8.0GT/x4 /pci@302/pci@2/pci@0/pci@4/nvme@0 ... ...
Con los nombres NAC correctos para las unidades NMVe de las ranuras 3, 4 y 5, la salida de prtdiag debería ser la siguiente:
======================================== IO Devices ======================================= Slot + Bus Name + Model Max Speed Cur Speed Status Type Path /Width /Width ------------------------------------------------------------------------------------------- ... ... /SYS/DBP/NVME4 PCIE nvme-pciexclass,010802 8.0GT/x4 8.0GT/x4 /pci@300/pci@2/pci@0/pci@6/nvme@0 /SYS/DBP/NVME3 PCIE nvme-pciexclass,010802 8.0GT/x4 8.0GT/x4 /pci@300/pci@2/pci@0/pci@7/nvme@0 /SYS/MB/PCIE5 PCIE nvme-pciexclass,010802 8.0GT/x4 8.0GT/x4 /pci@300/pci@2/pci@0/pci@15/nvme@0 ... ...
Solución alternativa: use el comando format o el comando diskinfo para encontrar los nombres NAC correctos y las rutas de dispositivo asociadas para las unidades NVMe con esta configuración. Por ejemplo, escriba:
# diskinfo D:devchassis-path c:occupant-compdev ----------------------------------- ------------------ /dev/chassis/SYS/DBP/NVME0/disk c14t1d0 /dev/chassis/SYS/DBP/NVME1/disk c15t1d0 /dev/chassis/SYS/DBP/NVME2/disk c16t1d0 /dev/chassis/SYS/DBP/NVME3/disk c7t1d0 /dev/chassis/SYS/DBP/NVME4/disk c6t1d0 /dev/chassis/SYS/DBP/NVME5/disk c13t1d0 /dev/chassis/SYS/DBP/NVME6/disk c9t1d0 /dev/chassis/SYS/DBP/NVME7/disk c11t1d0 /dev/chassis/SYS/DBP/NVME8/disk c12t1d0 /dev/chassis/SYS/DBP/NVME9/disk c3t1d0 /dev/chassis/SYS/DBP/NVME10/disk c4t1d0 /dev/chassis/SYS/DBP/NVME11/disk c5t1d0 ...
# format Searching for disks...done AVAILABLE DISK SELECTIONS: 0. c14t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@302/pci@2/pci@0/pci@17/pci@0/pci@4/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME0/disk 1. c15t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@302/pci@2/pci@0/pci@17/pci@0/pci@5/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME1/disk 2. c16t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@302/pci@2/pci@0/pci@17/pci@0/pci@6/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME2/disk 3. c7t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@300/pci@2/pci@0/pci@7/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME3/disk 4. c6t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@300/pci@2/pci@0/pci@6/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME4/disk 5. c13t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@302/pci@2/pci@0/pci@4/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME5/disk 6. c9t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@302/pci@1/pci@0/pci@13/pci@0/pci@4/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME6/disk 7. c11t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@302/pci@1/pci@0/pci@13/pci@0/pci@5/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME7/disk 8. c12t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@302/pci@1/pci@0/pci@13/pci@0/pci@6/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME8/disk 9. c3t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@300/pci@1/pci@0/pci@11/pci@0/pci@4/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME9/disk 10. c4t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@300/pci@1/pci@0/pci@11/pci@0/pci@5/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME10/disk 11. c5t1d0 <INTEL-SSDPE2ME016T4S-8DV1-1.46TB> /pci@300/pci@1/pci@0/pci@11/pci@0/pci@6/nvme@0/disk@1 /dev/chassis/SYS/DBP/NVME11/disk
Para obtener más información sobre los errores de unidades, consulte Los sistemas de placa posterior de 12 y 24 discos S7-2L no pueden mostrar los discos (18712182).