EvSctpTransRej

Measurement ID
9425
Measurement Group
Transport Exception
Measurement Type
Max
Measurement Dimension
Arrayed (per Transport)
Description
The number of times SCTP Transport has been rejected due to remote IP addresses validation failure based on SCTP Multihoming mode. This is valid only for SCTP Transports.
Collection Interval
30 min
Peg Condition
Each time the association has been rejected due to IP address validation failure in the SCTP INITs/INIT-ACKs transmitted by the Adjacent Node.
Measurement Scope
NE, Server

Recovery


  1. If all is well, this measurement should have a zero value. A non-zero value indicates that the Adjacent Node has attempted to connect to the Peer IP Address at least once and but the connection attempt was rejected because the IP addresses advertised by the Adjacent Node failed validation.
  2. Otherwise:
    1. Transport status can be viewed at Main Menu > Transport Manager > Maintenance > Transport.
    2. Check the event history log at Main Menu > Alarms & Events > View History, looking for Events 19411 - SCTP Transport closed due to failure of multihoming validation or 19412 - SCTP Transport Transport Configuration Mismatch which provide more details as to the actual cause of the failure.
    3. Verify that the SCTP validation mode is as desired.
    4. Verify that the Adjacent Node that represents the far-end of the association is configured with the correct address at Main Menu > Transport Manager > Configuration > Adjacent Node.
    5. Verify that the remote port configured at Main Menu > Transport Manager > Configuration > Transport for the association correctly identifies the port that the Adjacent node is listening on for SCTOp connections.
    6. It is recommended to contact My Oracle Support for assistance if needed.