EvSctpAdjPToDwn
- Measurement ID
- 9424
- Measurement Group
- Transport Exception
- Measurement Type
- Max
- Measurement Dimension
- Arrayed (per Transport)
- Description
- The number of times a configured IP Address of an Adjacent Node goes from Available to Unavailable.
- Collection Interval
- 30 min
- Peg Condition
- Each time reachability to a configured IP address of an Adjacent Node is lost, indicating a fault in the path to that address was detected.
- Measurement Scope
- NE, Server
Recovery
- If all is well, this measurement should have a zero value. A non-zero value indicates a path fault to that address was detected.
- Otherwise:
- Check the event history log at , looking for Event 19409 - Message Rejected by ACL Filtering which provide more details as to the actual cause of the failure.
- Verify the Adjacent Node that represents the far-end of the association is configured with the correct address at .
- Verify the IP network connectivity between the MP server and the Adjacent Node's IP address using a ping or traceroute command
- It is recommended to contact My Oracle Support for assistance if needed.