Table 3-9 describes the fields on the Message Priority Configuration Sets View, Edit, and Insert pages. Data Input Notes apply only to the Insert and Edit pages; the View page is read-only.
Table 3-9 Message Priority Configuration Set Elements
Field (* indicates a required field) | Description | Data Input Notes |
---|---|---|
* Message Priority Configuration Set Name | Unique name of the Message Priority Configuration Set. | Format: Case-sensitive string: alphanumeric and underscore (_); must contain at least one alpha and cannot begin with a digit. Range: 1 - 32 characters |
* Message Priority Rules | The number of Message Priority Rules defined in the Message Priority Configuration Set. | |
Application ID | The Application ID used to filter incoming Diameter messages. | Format: List Range: Select from the configured Application IDs.
Note: An asterisk (*) matches any Application ID. |
Application Name (view only) | The name of the application associated with the Application ID. | |
Command Code | The Command Code used to filter incoming Diameter messages. An ECC is a Command Code that also takes into account the value of a specific AVP for that Command Code that gives the "true" command type (for example, CCR-I, CCR-U, and so on). Note: This list of configured Command Codes includes Extended Command-Codes (ECC) immediately after their parent Command-Code. |
Format: List Range: Select from the configured Command Codes.
Note: An asterisk (*) matches any Command Code. |
Command Code Name (view only) | The name of the command associated with the Command Code. | |
Message Priority | The message priority assigned to incoming messages that match the combination of Application ID and Command Code. | Format: List Range: 0 - Max (Maximum Normal Request Priority as defined in System Options) |