Configuring Gateway Only Settings
If you are using the H.323 interface as a gateway, you might want to set registration time-out and address prefix parameters.
To configure gateway only settings:
-
registration-ttl—Enter the number of seconds before a registration becomes invalid. This value is used during the initial registration process. However, when a registration is confirmed, the time-to-live (TTL) value set by the gatekeeper in the Registration Confirm (RCF) message overrides this value. The default value is
120. The valid range is:
-
Minimum—0
-
Maximum—4294967295
-
-
prefixes—Enter a list of prefixes for this H.323 interface. Possible prefix types include:
-
H.323 ID | E.164 | URL | IPv4 address
These prefixes are sent from a gateway interface to a gatekeeper and indicate valid prefixes accepted by that interface for incoming calls. They are used if the interface is configured as a gateway (the is-gateway parameter is set to enabled).
Your entries for this parameter must appear as they do in the following example:
e164=17817566800 url=http://www.companyname.com h323-ID=xyz email=user@companyname.com ipAddress=63.67.143.4:2000
-