This chapter describes Oracle Database Appliance features. There are several versions of Oracle Database Appliance and this document covers all versions:
Oracle Database Appliance X6-2-HA (High Availability)
Oracle Database Appliance X6-2S/X6-2M/X6-2L
Oracle Database Appliance X5-2
Oracle Database Appliance X4-2
Oracle Database Appliance X3-2
Oracle Database Appliance Version 1 (also referred to as "original version" or "V1")
For information about Oracle Database Appliance features:
The following sections describe the components and capabilities of the different versions of Oracle Database Appliance.
Oracle Database Appliance X6-2 Series Components and Capabilities
Oracle Database Appliance Version 1 and Models X3-2, X4-2 and X5-2 Components and Capabilities
The following table lists supported components and capabilities for the Oracle Database Appliance X6-2 series systems.
Component | Oracle Database Appliance X6-2S | Oracle Database Appliance X6-2M | Oracle Database Appliance X6-2L | Oracle Database Appliance X6-2-HA |
---|---|---|---|---|
Server node |
Single 1RU server. |
Single 1RU server. |
Single 2RU server. |
Two 1RU server nodes. Each server node operates independently from the other server node. The lower server node is node 0 (SN0). The upper server node is node 1 (SN1). |
CPUs |
One 10-core 2.2 GHz Intel Xeon E5-2630 V4 processor. |
Two 10-core 2.2 GHz Intel Xeon E5-2630 V4 processors. |
Two 10-core 2.2 GHz Intel Xeon E5-2630 V4 processors. |
Two 10-core 2.2 GHz Intel Xeon E5-2630 V4 processors per server node. |
Memory |
128 GB – four 32 GB low-voltage DDR4 RDIMMs rated at 2400 MT/s (2133 MT/s actual maximum).
Note - Optional memory expansion to 384 GB. See Optional Component Installation. |
256 GB – eight 32 GB low-voltage DDR4 RDIMMs rated at 2400 MT/s (2133 MT/s actual maximum).
Note - Optional memory expansion to 512 GB or 768 GB. See Optional Component Installation. |
256 GB – eight 32 GB low-voltage DDR4 RDIMMs rated at 2400 MT/s (2133 MT/s actual maximum).
Note - Optional memory expansion to 512 GB or 768 GB. See Optional Component Installation. |
256 GB – eight 32 GB low-voltage DDR4 RDIMMs rated at 2400 MT/s per server node (2133 MT/s actual maximum).
Note - Optional memory expansion to 512 GB or 768 GB per server. Both server nodes must have the same amount of memory. See Optional Component Installation. |
Storage devices |
The server includes:
Note - Two optional NVMe SSDs can be added. See Optional Component Installation. |
The server includes:
Note - Two optional NVMe SSDs can be added. See Optional Component Installation. |
The server includes:
|
Each server node includes:
The 4RU storage shelf and the optional storage expansion shelf each include:
|
USB 2.0 ports |
Six total (two front, two rear and two internal) per server node. |
Six total (two front, two rear and two internal) per server node. |
Six total (two front, two rear and two internal) per server node. |
Six total (two front, two rear and two internal) per server node. |
PCI Express (PCIe) I/O slots |
Three external and one internal low-profile PCIe Gen-3 slots. They contain:
|
Three external and one internal low-profile PCIe Gen-3 slots. They contain:
|
Six external internal low-profile PCIe Gen-3 slots. They contain:
|
Three external and one internal low-profile PCIe Gen-3 slots for each server node. They contain:
|
Cluster device |
N/A |
N/A |
N/A |
One integrated cluster device with node-to-node interconnection is provided on each server node through two InfiniBand ports with QSFP+ connections. Alternatively, you have the option of creating the node-to-node interconnection using two of each server node's four 10 GbE network interface ports with RJ-45 connections.
Note - This alternative configuration is used when the Oracle Database Appliance X6-2-HA is ordered with a Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter instead of the standard InfiniBand adapter when an Ethernet fiber connection to the data center or public network is required. |
SAS ports |
Two internal SAS3 ports |
Two internal SAS3 ports |
Two internal SAS3 ports (only one used for rear drives) |
Two internal SAS3 and four external SAS3 ports on each server node. Six SAS3 ports on the storage shelf. Six SAS3 ports on the storage expansion shelf. |
Onboard Ethernet ports |
Two functional auto-sensing 100/1000/10000 Base-T Ethernet ports with RJ-45 connectors located on the back of the server.
Note - Ethernet ports NET 2 and NET 3 are nonfunctional in single-processor systems. |
Four auto-sensing 100/1000/10000 Base-T Ethernet ports with RJ-45 connectors located on the back of the server. |
Four auto-sensing 100/1000/10000 Base-T Ethernet ports with RJ-45 connectors located on the back of the server. |
Four auto-sensing 100/1000/10000 Base-T Ethernet ports with RJ-45 connectors located on the back of each server node. |
Network management (NET MGT) port |
One 10/100/1000Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on each server node rear panel. |
One 10/100/1000Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on each server node rear panel. |
One 10/100/1000Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on each server node rear panel. |
One 10/100/1000Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on each server node rear panel. |
Serial management (SER MGT) port |
One RS-232 RJ-45 serial port on each server node rear panel. |
One RS-232 RJ-45 serial port on each server node rear panel. |
One RS-232 RJ-45 serial port on each server node rear panel. |
One RS-232 RJ-45 serial port on each server node rear panel. |
VGA port |
One high-density HD-15 video port on each server node rear panel. |
One high-density HD-15 video port on each server node rear panel. |
One high-density HD-15 video port on each server node rear panel. |
One high-density HD-15 video port on each server node rear panel. |
Service Processor (SP) |
Each server node has a service processor with the following features:
|
Each server node has a service processor with the following features:
|
Each server node has a service processor with the following features:
|
Each server node has a service processor with the following features:
|
Power supplies |
Two hot-pluggable power supplies. |
Two hot-pluggable power supplies. |
Two hot-pluggable power supplies. |
Two hot-pluggable power supplies per server node and per storage shelf. |
Cooling fans |
Four 40-mm, hot-pluggable fan modules per server node for chassis cooling. Each fan module contains two counter-rotating fan pairs (four rotors total). Each power supply has its own cooling fans. |
Four 40-mm, hot-pluggable fan modules per server node for chassis cooling. Each fan module contains two counter-rotating fan pairs (four rotors total). Each power supply has its own cooling fans. |
Four 80-mm, hot-pluggable fan modules per server node for chassis cooling. Each fan module contains two counter-rotating fan pairs (four rotors total). Each power supply has its own cooling fans. |
Four 40-mm, hot-pluggable fan modules per server node for chassis cooling. Each fan module contains two counter-rotating fan pairs (four rotors total). Each power supply (server node and storage shelf) has its own cooling fans. |
Operating system |
Oracle Linux. |
Oracle Linux. |
Oracle Linux. |
Oracle Linux. |
Management software |
Oracle Integrated Lights Out Manager (ILOM) 3.2. |
Oracle Integrated Lights Out Manager (ILOM) 3.2. |
Oracle Integrated Lights Out Manager (ILOM) 3.2. |
Oracle Integrated Lights Out Manager (ILOM) 3.2. |
The following table lists supported components and capabilities for the Oracle Database Appliance Version 1, Oracle Database Appliance X3-2, Oracle Database Appliance X4-2 and Oracle Database Appliance X5-2.
Component | Oracle Database Appliance (Version 1) | Oracle Database Appliance X3-2 | Oracle Database Appliance X4-2 | Oracle Database Appliance X5-2 |
---|---|---|---|---|
Server node |
Two server nodes per chassis. Each server node operates independently from the other server node. The lower server node is node 0 (SN0). The upper server node is node 1 (SN1). |
Two server nodes. Each server node operates independently from the other server node. The lower server node is node 0 (SN0). The upper server node is node 1 (SN1). |
Two server nodes. Each server node operates independently from the other server node. The lower server node is node 0 (SN0). The upper server node is node 1 (SN1). |
Two server nodes. Each server node operates independently from the other server node. The lower server node is node 0 (SN0). The upper server node is node 1 (SN1). |
CPUs |
Two 6-core 3.06 GHz Intel Xeon X5675 processors per server node. |
Two 8-core 2.9 GHz Intel Xeon E5-2690 processors per server node. |
Two 12-core 2.7 GHz Intel Xeon E5-2697 v2 processors per server node. |
Two 18-core 2.3 GHz Intel Xeon E5-2699 v3 processors per server node. |
Memory |
96 GB – six 8 GB low-voltage DDR3 RDIMMs (single or dual rank) at 1333 MT/s per server node.
Note - Quad-rank DIMMs are not supported. |
256 GB – sixteen 16 GB low-voltage DDR3 RDIMMs at 1600 MT/s per server node. |
256 GB – sixteen 16 GB low-voltage DDR3 RDIMMs at 1600 MT/s per server node. |
256 GB – eight 32 GB low-voltage DDR4 LRDIMMs at 2133 MT/s per server node.
Note - Optional memory expansion to 512 GB or 768 GB. Both server nodes must have the same amount of memory. See Optional Component Installation. |
Storage devices |
Each server node includes:
|
Each server node includes:
The storage shelf and the optional storage expansion shelf each include:
|
Each server node includes:
The storage shelf and the optional storage expansion shelf each include:
|
Each server node includes:
The storage shelf and the optional storage expansion shelf each include:
|
USB 2.0 ports |
Two rear and one internal for each server node. |
Six total (two front, two rear and two internal) per server node. |
Six total (two front, two rear and two internal) per server node. |
Six total (two front, two rear and two internal) per server node. |
PCI Express (PCIe) I/O slots |
Three external low-profile PCIe Gen-2 slots (x8) for each server node. They contain:
One internal low-profile PCIe Gen-2 slot (x8) with a Dual-port Internal 6Gb/s SAS2 host bus adapter |
Three external and one internal low-profile PCIe Gen-3 slots for each server node. They contain:
|
Three external and one internal low-profile PCIe Gen-3 slots for each server node. They contain:
|
Three external and one internal low-profile PCIe Gen-3 slots for each server node. They contain:
|
Cluster device |
One integrated cluster device with node-to-node connections is provided on each server node. Each integrated cluster device provides two internal 1 GbE network interface ports and two internal dual-port UART ports. |
One integrated cluster device with node-to-node interconnection is provided on each server node through two 10 GbE network interface ports with RJ-45 connections. |
One integrated cluster device with node-to-node interconnection is provided on each server node through two 10 GbE network interface ports with dual-rate SFP+ connections. Alternatively, you have the option of creating the node-to-node interconnection using two of each server node's four 10 GbE network interface ports with RJ-45 connections. Refer to the Oracle Database Appliance Getting Started Guide for more information.
|
One integrated cluster device with node-to-node interconnection is provided on each server node through two InfiniBand ports with QSFP+ connections. Alternatively, you have the option of creating the node-to-node interconnection using two of each server node's four 10 GbE network interface ports with RJ-45 connections. Refer to the Oracle Database Appliance Getting Started Guide for more information.
|
SAS ports |
N/A |
Two internal SAS2 and four external SAS2 ports on each server node. Six SAS2 ports on the storage shelf. Six SAS2 ports on the storage expansion shelf. |
Two internal SAS2 and four external SAS2 ports on each server node. Six SAS2 ports on the storage shelf. Six SAS2 ports on the storage expansion shelf. |
Two internal SAS3 and four external SAS3 ports on each server node. Six SAS2 ports on the storage shelf. Six SAS2 ports on the storage expansion shelf. |
Onboard Ethernet ports |
Two 1 GbE network interface ports with RJ-45 connectors located on the back panel of each server node. |
Four auto-sensing 100/1000/10000 Base-T Ethernet ports with RJ-45 connectors located on the back of each server node. |
Four auto-sensing 100/1000/10000 Base-T Ethernet ports with RJ-45 connectors located on the back of each server node. |
Four auto-sensing 100/1000/10000 Base-T Ethernet ports with RJ-45 connectors located on the back of each server node.
Note - Optionally, you can purchase the Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter as a replacement for the standard InfiniBand adapter if an Ethernet fiber connection to the data center or public network is required. See Optional Component Installation. |
Network management (NET MGT) port |
One 10/100Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on the back panel of each server node. |
One 10/100Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on the back panel of each server node. |
One 10/100Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on the back panel of each server node. |
One 10/100/1000Base-T network interface port with RJ-45 connector dedicated to the service processor (SP) on the back panel of each server node. |
Serial management (SER MGT) port |
One RS-232 RJ-45 serial port on the back panel of each server node. |
One RS-232 RJ-45 serial port on the back panel of each server node. |
One RS-232 RJ-45 serial port on the back panel of each server node. |
One RS-232 RJ-45 serial port on the back panel of each server node. |
VGA port |
One high-density HD-15 video port on the back panel of each server node. |
One high-density HD-15 video port on the back panel of each server node. |
One high-density HD-15 video port on the back panel of each server node. |
One high-density HD-15 video port on the back panel of each server node. |
Service Processor (SP) |
Each server node has a service processor with the following features:
|
Each server node has a service processor with the following features:
|
Each server node has a service processor with the following features:
|
Each server node has a service processor with the following features:
|
Power supplies |
Two hot-pluggable power supplies per chassis. |
Two hot-pluggable power supplies per server node and per storage shelf. |
Two hot-pluggable power supplies per server node and per storage shelf. |
Two hot-pluggable power supplies per server node and per storage shelf. |
Cooling fans |
Two redundant hot-pluggable fan modules per server node. |
Four 40-mm, hot-pluggable fan modules per server node for chassis cooling. Each fan module contains two counter-rotating fan pairs (four rotors total). Each power supply (server node and storage shelf) has its own cooling fans. |
Four 40-mm, hot-pluggable fan modules per server node for chassis cooling. Each fan module contains two counter-rotating fan pairs (four rotors total). Each power supply (server node and storage shelf) has its own cooling fans. |
Four 40-mm, hot-pluggable fan modules per server node for chassis cooling. Each fan module contains two counter-rotating fan pairs (four rotors total). Each power supply (server node and storage shelf) has its own cooling fans. |
Operating system |
Oracle Linux. |
Oracle Linux. |
Oracle Linux. |
Oracle Linux. |
Management software |
Oracle Integrated Lights Out Manager (ILOM) 3.0. |
Oracle Integrated Lights Out Manager (ILOM) 3.1. |
Oracle Integrated Lights Out Manager (ILOM) 3.1. |
Oracle Integrated Lights Out Manager (ILOM) 3.2. |
This section describes Oracle Database Appliance X6-2S/X6-2M/X6-2L front and back panels. If you have Oracle Database Appliance X6-2-HA, see Oracle Database Appliance X6-2-HA Front and Back Panels. If you have Oracle Database Appliance X5-2, see Oracle Database Appliance X5-2 Front and Back Panels. If you have Oracle Database Appliance X3-2 or Oracle Database Appliance X4-2, see Oracle Database Appliance X3-2/X4-2 Front and Back Panels. If you have Oracle Database Appliance Version 1, see Oracle Database Appliance Version 1 Front and Back Panels.
Oracle Database Appliance X6-2S and Oracle Database Appliance X6-2M servers each occupy 1RU.
The following figure shows the components on the front panel of an Oracle Database Appliance X6-2S/X6-2M.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Product Serial Number (PSN) label and Radio Frequency Identification (RFID) tag |
8 |
Fan Fault LED: amber |
2 |
Locate LED/button: white |
9 |
Power Supply (PS) Fault LED: amber |
3 |
USB 2.0 connectors (2) |
10 |
System Over Temperature Warning LED: amber |
4 |
SP OK LED: green |
11 - 12 |
HDD 0 - HDD 1 (boot drives) |
5 |
Service Required LED: amber |
13 - 16 |
NVMe0, NVMe1, NVMe2 (or HDD filler), NVMe3 (or HDD filler) |
6 |
Power/OK LED: green |
17 - 18 |
HDD filler |
7 |
Power button |
19 |
DVD filler |
The following figure shows the components on the back panel of an Oracle Database Appliance X6-2S/X6-2M.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Power Supply (PS) 0 with fan module |
9 |
NET MGT port. Service processor 10/100/1000Base-T network interface port with RJ-45 connector used to connect to Oracle Integrated Lights Out Manager (ILOM)
Caution -
The management ports are intended for use by service engineers only.
|
2 |
Power Supply (PS) 0 status indicators: Service Required LED: amber, AC OK LED: green |
10 |
SER MGT port. Service processor RJ-45 serial port used to connect to Oracle ILOM
Caution -
The management ports are intended for use by service engineers only.
|
3 |
Power Supply (PS) 1 with fan module |
11 |
10 GbE network interface port with RJ-45 connector
Note - Ethernet ports NET 2 and NET 3 are nonfunctional in Oracle Database Appliance X6-2S. |
4 |
Power Supply (PS) 1 status indicators: Service Required LED: amber, AC OK LED: green |
12 |
10 GbE network interface port with RJ-45 connector
Note - Ethernet ports NET 2 and NET 3 are nonfunctional in Oracle Database Appliance X6-2S. |
5 |
System status indicators: Locate LED: white, Service Required LED: amber, Power/OK LED: green |
13 |
10 GbE network interface port with RJ-45 connector |
6 |
PCIe card slot 1: empty |
14 |
10 GbE network interface port with RJ-45 connector |
7 |
PCIe card slot 2: NVMe Switch PCIe Card |
15 |
USB 2.0 connectors (2) |
8 |
PCIe card slot 3. Dual 10 GbE SFP+ PCIe 2.0 Low Profile Adapter. Provides two 10 GbE dual-rate SFP+ ports. PCIe card slot 4 (internal). Dual-port Internal 12Gb/s SAS3 host bus adapter. Provides support for the server's internal SAS storage. |
16 |
DB-15 video connector |
The Oracle Database Appliance X6-2L server occupies 2RU.
The following figure shows the components on the front panel of an Oracle Database Appliance X6-2L.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Locate LED/button: white |
6 |
Power button |
2 |
Service Required LED: amber |
7 - 15 |
NVMe0, NVMe1, NVMe2 (or HDD filler), NVMe3, NVMe4, NVMe5 (or HDD filler), NVMe6, NVMe7, NVMe8 (or HDD filler)
Note - Slots NVMe2 (callout 9), NVMe5 (callout 12) and NVMe8 (callout 15) are available for storage expansion on base configuration models. See Optional Component Installation. |
3 |
Power/OK LED: green |
16 - 18 |
Slots NVMe9 - NVMe11
Note - These NVMe slots are not supported for use with this product. |
4 |
Product Serial Number (PSN) label and Radio Frequency Identification (RFID) tag |
19 |
Top Fan Fault LED: amber Power Supply (PS) Fault LED: amber System Over Temperature Warning LED: amber |
5 |
SP OK LED: green |
20 |
USB 2.0 connectors (2) |
The following figure shows the components on the Oracle Database Appliance X6-2L back panel.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
rear HDD 0 (boot drive) |
9 |
System status indicators: Locate LED: white, Service Required LED: amber, Power/OK LED: green |
2 |
rear HDD 1 (boot drive) |
10 |
SER MGT port. Service processor RJ-45 serial port used to connect to Oracle ILOM
Caution -
The management ports are intended for use by service engineers only.
|
3 |
Power Supply (PS) 0 with fan module Power Supply (PS) 0 status indicators: Service Required LED: amber, AC OK LED: green |
11 |
NET MGT port. Service processor 10/100/1000Base-T network interface port with RJ-45 connector used to connect to Oracle Integrated Lights Out Manager (ILOM)
Caution -
The management ports are intended for use by service engineers only.
|
4 |
Power Supply (PS) 1 with fan module Power Supply (PS) 1 status indicators: Service Required LED: amber, AC OK LED: green |
12 |
USB 2.0 connectors (2) |
5 |
PCIe card slot 1: Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter |
13 |
DB-15 video connector |
6 |
PCIe card slot 2: Oracle NVMe Switch PCIe card |
14 |
PCIe card slot 4: Filler panel |
7 |
PCIe card slot 3: Oracle Storage 12 Gb SAS3 PCIe RAID Internal HBA |
15 |
PCIe card slot 5: Oracle NVMe Switch PCIe card |
8 |
Four 10 GbE network interface ports with RJ-45 connectors |
16 |
PCIe card slot 6: Oracle NVMe Switch PCIe card |
This section describes Oracle Database Appliance X6-2-HA front and back panels. If you have Oracle Database Appliance X6-2S/X6-2M/X6-2L, see Oracle Database Appliance X6-2S/X6-2M/X6-2L Front and Back Panels. If you have Oracle Database Appliance X5-2, see Oracle Database Appliance X5-2 Front and Back Panels. If you have Oracle Database Appliance X3-2 or Oracle Database Appliance X4-2, see Oracle Database Appliance X3-2/X4-2 Front and Back Panels. If you have Oracle Database Appliance Version 1, see Oracle Database Appliance Version 1 Front and Back Panels.
Oracle Database Appliance X6-2-HA includes two server nodes (two Oracle Server X6-2's) and an Oracle DE3-24C storage shelf. The entire unit occupies 6RU. The optional storage expansion shelf requires an additional 4RU, increasing the total to 10RU.
The following figure shows the front of Oracle Database Appliance X6-2-HA with an optional storage expansion shelf.
Callout | Description |
---|---|
1 |
Server node 1 |
2 |
Server node 0 |
3 |
Storage shelf (DE3-24C) |
4 |
Optional storage expansion shelf (DE3-24C) |
The following figure shows the components on the front panel of an Oracle Database Appliance X6-2-HA server node.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Product Serial Number (PSN) label and Radio Frequency Identification (RFID) tag |
8 |
Fan Fault LED: amber |
2 |
Locate LED/button: white |
9 |
Power Supply (PS) Fault LED: amber |
3 |
USB 2.0 connectors (2) |
10 |
System Over Temperature Warning LED: amber |
4 |
SP OK LED: green |
11 |
HDD 0 (boot drive) |
5 |
Service Required LED: amber |
12 |
HDD 1 (boot drive) |
6 |
Power/OK LED: green |
13 - 18 |
HDD filler |
7 |
Power button |
19 |
DVD filler |
Note:
When contacting Oracle Support Services, use the Top Level Identifier (TLI) instead of the serial number. You can find the TLI by looking at the top of either server node or on the top of the storage shelf. For details, see Technical Support.The following figure shows the Oracle Database Appliance X6-2-HA storage shelf front panel features.
Note:
In the base configuration storage shelf, disk slots 10-19 are empty (filler panels only). The system deployment will fail if the placement of the disks in the base configuration is changed.You have the option of upgrading the base configuration storage shelf to add an additional ten 1.6 TB SAS SSDs in slots 10-19. See Optional Component Installation. Upgrading the base configuration to a fully populated storage shelf will allow you to add a storage expansion shelf later, if needed.
Callout | Description |
---|---|
1 |
Storage shelf Locate indicator |
2 |
Storage shelf fault indicator |
3 |
Storage shelf OK/power indicator |
4 |
Storage shelf power supply fault indicator |
5 |
Storage shelf IO module fault indicator |
6 |
Drive Ready-to-Remove indicator |
7 |
Drive fault indicator |
8 |
Drive power/activity indicator |
This section describes the back panel features for Oracle Database Appliance X6-2-HA. The following figure shows the Oracle Database Appliance X6-2-HA.
Callout | Description |
---|---|
1 |
Server node 1 |
2 |
Server node 0 |
3 |
Storage shelf (DE3-24C) |
4 |
Optional storage expansion shelf (DE3-24C) |
The following figure shows the components on the Oracle Database Appliance X6-2-HA server node back panel.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Power Supply (PS) 0 with fan module |
9 |
NET MGT port. Service processor 10/100/1000Base-T network interface port with RJ-45 connector used to connect to Oracle Integrated Lights Out Manager (ILOM)
Caution -
The management ports are intended for use by service engineers only.
|
2 |
Power Supply (PS) 0 status indicators: Service Required LED: amber, AC OK LED: green |
10 |
SER MGT port. Service processor RJ-45 serial port used to connect to Oracle ILOM
Caution -
The management ports are intended for use by service engineers only.
|
3 |
Power Supply (PS) 1 with fan module |
11 |
10 GbE network interface port with RJ-45 connector |
4 |
Power Supply (PS) 1 status indicators: Service Required LED: amber, AC OK LED: green |
12 |
10 GbE network interface port with RJ-45 connector |
5 |
System status indicators: Locate LED: white, Service Required LED: amber, Power/OK LED: green |
13 |
10 GbE network interface port with RJ-45 connector |
6 |
Two interface options are available from the factory for the appliance:
|
14 |
10 GbE network interface port with RJ-45 connector |
7 |
PCIe card slot 2. Provides two SAS3 connectors used to connect the servers to the storage shelf and the storage expansion shelf. |
15 |
USB 2.0 connectors (2) |
8 |
PCIe card slot 3. Provides two SAS3 connectors used to connect the servers to the storage shelf and the storage expansion shelf. |
16 |
DB-15 video connector |
The following figure shows the Oracle Database Appliance X6-2-HA storage shelf back panel features.
Caution:
The network ports on the storage shelf are intended for use by service engineers only.Callout | Description |
---|---|
1 |
AC power indicator |
2 |
Fan fail indicator |
3 |
Power supply status indicator |
4 |
DC power fail indicator |
5 |
Power Supply with Fan Module 0 |
6 |
Service ports (reserved for Oracle Service only) |
7 |
SAS I/O module 1 |
8 |
SAS I/O module 0 |
9 |
Power Supply with Fan Module 1 |
This section describes Oracle Database Appliance X5-2 front and back panels. If you have Oracle Database Appliance X6-2 series, see Oracle Database Appliance X6-2S/X6-2M/X6-2L Front and Back Panels. If you have Oracle Database Appliance X6-2-HA, see Oracle Database Appliance X6-2-HA Front and Back Panels. If you have Oracle Database Appliance X3-2 or Oracle Database Appliance X4-2, see Oracle Database Appliance X3-2/X4-2 Front and Back Panels. If you have Oracle Database Appliance Version 1, see Oracle Database Appliance Version 1 Front and Back Panels.
Oracle Database Appliance X5-2 includes two server nodes (two Oracle Server X5-2's) and an Oracle DE2-24C storage shelf. The entire unit occupies 6RU. The optional storage expansion shelf requires an additional 4RU, increasing the total to 10RU.
The following figure shows the front of Oracle Database Appliance X5-2 with an optional storage expansion shelf.
Callout | Description |
---|---|
1 |
Server node 1 |
2 |
Server node 0 |
3 |
Storage shelf (DE2-24C) |
4 |
Optional storage expansion shelf (DE2-24C) |
The following figure shows the components on the front panel of an Oracle Database Appliance X5-2 server node.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Product Serial Number (PSN) label and Radio Frequency Identification (RFID) tag |
8 |
Fan Fault LED: amber |
2 |
Locate LED/button: white |
9 |
Power Supply (PS) Fault LED: amber |
3 |
USB 2.0 connectors (2) |
10 |
System Over Temperature Warning LED: amber |
4 |
SP OK LED: green |
11 |
HDD 0 (boot drive) |
5 |
Service Required LED: amber |
12 |
HDD 1 (boot drive) |
6 |
Power/OK LED: green |
13 - 18 |
HDD filler |
7 |
Power button |
19 |
DVD filler |
Note:
When contacting Oracle Support Services, use the Top Level Identifier (TLI) instead of the serial number. You can find the TLI by looking at the top of either server node or on the top of the storage shelf. For details, see Technical Support.The following figure shows the Oracle Database Appliance X5-2 storage shelf front panel features.
Callout | Description |
---|---|
1 |
Storage shelf OK/power indicator |
2 |
Storage shelf fault indicator |
3 |
Storage shelf Locate indicator |
4 |
Drive power/activity indicator |
5 |
Drive fault indicator |
This section describes the back panel features for Oracle Database Appliance X5-2. The following figure shows the Oracle Database Appliance X5-2.
Callout | Description |
---|---|
1 |
Server node 1 |
2 |
Server node 0 |
3 |
Storage shelf (DE2-24C) |
4 |
Optional storage expansion shelf (DE2-24C) |
The following figure shows the components on the Oracle Database Appliance X5-2 server node back panel.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Power Supply (PS) 0 with fan module |
9 |
NET MGT port. Service processor 10/100/1000Base-T network interface port with RJ-45 connector used to connect to Oracle Integrated Lights Out Manager (ILOM)
Caution -
The management ports are intended for use by service engineers only.
|
2 |
Power Supply (PS) 0 status indicators: Service Required LED: amber, AC OK LED: green |
10 |
SER MGT port. Service processor RJ-45 serial port used to connect to Oracle ILOM
Caution -
The management ports are intended for use by service engineers only.
|
3 |
Power Supply (PS) 1 with fan module |
11 |
10 GbE network interface port with RJ-45 connector |
4 |
Power Supply (PS) 1 status indicators: Service Required LED: amber, AC OK LED: green |
12 |
10 GbE network interface port with RJ-45 connector |
5 |
System status indicators: Locate LED: white, Service Required LED: amber, Power/OK LED: green |
13 |
10 GbE network interface port with RJ-45 connector |
6 |
PCIe card slot 1. Provides two InfiniBand network interface ports with QSFP+ connections for a private cluster interconnect between server nodes. Alternatively, you have the option of creating the node-to-node interconnection using two of each server node's four 10 GbE network interface ports with RJ-45 connections. Refer to the Oracle Database Appliance Getting Started Guide for more information.
|
14 |
10 GbE network interface port with RJ-45 connector |
7 |
PCIe card slot 2. Provides two SAS3 connectors used to connect the servers to the storage shelf and the storage expansion shelf. |
15 |
USB 2.0 connectors (2) |
8 |
PCIe card slot 3. Provides two SAS3 connectors used to connect the servers to the storage shelf and the storage expansion shelf. |
16 |
DB-15 video connector |
The following figure shows the Oracle Database Appliance X5-2 storage shelf back panel features.
Caution:
The network ports on the storage shelf are intended for use by service engineers only.Callout | Description |
---|---|
1 |
AC power fail indicator |
2 |
Power supply status indicator |
3 |
Fan fail indicator |
4 |
DC power fail indicator |
5 |
Service ports (reserved for Oracle Service only) |
6 |
SAS I/O module 1 |
7 |
Power Supply with Fan Module 2 |
8 |
SAS I/O module 0 Power Supply with Fan Module 1 |
9 |
Power Supply with Fan Module 1 |
This section describes Oracle Database ApplianceX3-2/X4-2 front and back panels. If you have Oracle Database Appliance X6-2 series, see Oracle Database Appliance X6-2S/X6-2M/X6-2L Front and Back Panels. If you have Oracle Database Appliance X6-2-HA, see Oracle Database Appliance X6-2-HA Front and Back Panels. If you have Oracle Database Appliance X5-2, see Oracle Database Appliance X5-2 Front and Back Panels. If you have Oracle Database Appliance Version 1, see Oracle Database Appliance Version 1 Front and Back Panels.
Oracle Database Appliance X3-2/X4-2 includes two server nodes (either two Sun Server X3-2's, or two Sun Server X4-2's) and an Oracle DE2-24P storage shelf. The entire unit occupies 4RU. The optional DE2-24P storage expansion shelf requires an additional 2RU, increasing the total to 6RU.
The following figure shows the front of Oracle Database Appliance X3-2 with an optional storage expansion shelf. Except for product labeling, Oracle Database Appliance X4-2 is identical in appearance.
Callout | Description |
---|---|
1 |
Server node 1 |
2 |
Server node 0 |
3 |
Storage shelf (DE2-24P) |
4 |
Optional storage expansion shelf (DE2-24P) |
The following figure shows the components on the front panel of an Oracle Database Appliance X3-2/X4-2 server node.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Product Serial Number (PSN) label and Radio Frequency Identification (RFID) tag |
10 |
System Over Temperature Warning LED: amber |
2 |
Locate LED/button: white |
11 |
HDD 0 (boot drive) |
3 |
USB 2.0 connectors (2) |
12 |
HDD 1 (boot drive) |
4 |
SP OK LED: green |
13 |
HDD filler |
5 |
Service Required LED: amber |
14 |
HDD filler |
6 |
Power/OK LED: green |
15 |
HDD filler |
7 |
Power button |
16 |
HDD filler |
8 |
Fan Fault LED: amber |
17 |
HDD filler |
9 |
Power Supply (PS) Fault LED: amber |
18 |
HDD filler |
Note:
When contacting Oracle Support Services, use the Top Level Identifier (TLI) instead of the serial number. You can find the TLI by looking at the top of either server node or on the top of the storage shelf. For details, see Technical Support.The following figure shows the Oracle Database Appliance X3-2/X4-2 storage shelf front panel features.
Callout | Description |
---|---|
1 |
Storage shelf OK/power indicator |
2 |
Storage shelf fault indicator |
3 |
Storage shelf Locate indicator |
4 |
Drive fault indicator |
5 |
Drive power/activity indicator |
This section describes the back panel features for Oracle Database Appliance X3-2/X4-2. The following figure shows the Oracle Database Appliance X4-2. The Oracle Database Appliance X3-2 and Oracle Database Appliance X4-2 are identical except for the network card in PCIe slot 1 (see Server Node Back Panel Features).
Callout | Description |
---|---|
1 |
Server node 1 |
2 |
Server node 0 |
3 |
Storage shelf (DE2-24P) |
4 |
Optional storage expansion shelf (DE2-24P) |
The following figure shows the components on the Oracle Database Appliance X3-2/X4-2 server node back panel.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Power Supply (PS) 0 with fan module |
9 |
NET MGT port. Service processor 10/100BASE-T network interface port with RJ-45 connector used to connect to Oracle Integrated Lights Out Manager (ILOM)
Caution -
The management ports are intended for use by service engineers only.
|
2 |
Power Supply (PS) 0 status indicators: Service Required LED: amber, AC OK LED: green |
10 |
SER MGT port. Service processor RJ-45 serial port used to connect to Oracle ILOM
Caution -
The management ports are intended for use by service engineers only.
|
3 |
Power Supply (PS) 1 with fan module |
11 |
10 GbE network interface port with RJ-45 connector |
4 |
Power Supply (PS) 1 status indicators: Service Required LED: amber, AC OK LED: green |
12 |
10 GbE network interface port with RJ-45 connector |
5 |
System status indicators: Locate LED: white, Service Required LED: amber, Power/OK LED: green |
13 |
10 GbE network interface port with RJ-45 connector |
6 |
Oracle Database Appliance X4-2: PCIe card slot 1. Provides two 10 GbE dual-rate
SFP+ ports for a private cluster interconnect between server
nodes.
Alternatively, you have the option of creating the node-to-node interconnection using two of each server node's four 10 GbE network interface ports with RJ-45 connections. Refer to the Oracle Database Appliance Getting Started Guide for more information.
Oracle Database Appliance X3-2: PCIe card slot 1. Provides two 10 GbE network
interface ports with RJ-45 connectors for a private cluster interconnect between server
nodes.
|
14 |
10 GbE network interface port with RJ-45 connector |
7 |
PCIe card slot 2. Provides two SAS2 connectors used to connect the servers to the storage shelf and the storage expansion shelf. |
15 |
USB 2.0 connectors (2) |
8 |
PCIe card slot 3. Provides two SAS2 connectors used to connect the servers to the storage shelf and the storage expansion shelf. |
16 |
DB-15 video connector |
The following figure shows the Oracle Database Appliance X3-2/X4-2 storage shelf back panel features.
Caution:
The network ports on the storage shelf are intended for use by service engineers only.Callout | Description |
---|---|
1 |
AC power fail indicator |
2 |
Power supply status indicator |
3 |
Fan fail indicator |
4 |
DC power fail indicator |
5 |
Power Supply with Fan Module 0 |
6 |
Service ports (reserved for Oracle Service only) |
7 |
SAS I/O module 1 |
8 |
SAS I/O module 0 |
9 |
Power Supply with Fan Module 1 |
This section describes Oracle Database Appliance Version 1 front and back panels. If you have Oracle Database Appliance X6-2S/X6-2M/X6-2L, see Oracle Database Appliance X6-2S/X6-2M/X6-2L Front and Back Panels. If you have Oracle Database Appliance X6-2-HA, see Oracle Database Appliance X6-2-HA Front and Back Panels. If you have Oracle Database Appliance X5-2, see Oracle Database Appliance X5-2 Front and Back Panels. If you have Oracle Database Appliance X3-2 or Oracle Database Appliance X4-2, see Oracle Database Appliance X3-2/X4-2 Front and Back Panels.
Oracle Database Appliance Version 1 includes two server nodes, SN0 and SN1. SN0 is on the bottom and SN1 is on the top. Server nodes are also called system controllers.
The following figure shows Oracle Database Appliance Version 1 front panel and describes its components.
Note:
The system has two each of items 1 through 8; one for each server node. It has only one RFID, product serial number tag, and, drive map.Callout | Description |
---|---|
1 |
Locate button/LED (white) |
2 |
SP (service processor) OK LED (green = OK, amber = fault) |
3 |
Server Node Ready to Remove LED (blue) |
4 |
Service Required LED (amber) |
5 |
Power/OK LED (green) |
6 |
System Over Temperature LED (amber) |
7 |
Rear HDD (hard disk drive)/PS (power supply)/Fan Fault LED (amber) |
8 |
Power button (recessed) |
9 |
Drive map |
10 |
RFID (radio frequency identification) and product serial number tag |
The following figure shows Oracle Database Appliance Version 1 back panel and identifies the components on SN0. The components on SN1 are identical.
Callout | Description | Callout | Description |
---|---|---|---|
1 |
Power Supply Unit (PSU) |
8 |
Fans |
2 |
Locate button/LED (white) |
9 |
SER MGT port. Service processor RJ-45 serial port used to connect to Oracle ILOM
Caution -
The management ports are intended for use by service engineers only.
|
3 |
Host nonmaskable interrupt (NMI) and SP reset recessed switches |
10 |
Dual onboard 1 GbE network interface ports with RJ-45 connectors |
4 |
Status LEDs:
|
11 |
USB ports |
5 |
External MiniSAS ports (2 per server node) – Reserved. Do not use or connect cables to these ports |
12 |
NET MGT port. Service processor 10/100BASE-T network interface port with RJ-45 connector used to connect to Oracle Integrated Lights Out Manager (ILOM)
Caution -
The management ports are intended for use by service engineers only.
|
6 |
PCI Express (PCIe) slot 0 – Dual 10 GbE network interface ports |
13 |
Video connector to console |
7 |
PCIe slot 1 – Quad 1 GbE network interface ports with RJ-45 connectors |
14 |
Rear hard disk drives (RHDDs) (boot drives; 2 per server node)
Note - The RHDDs are behind hinged access panels. |
This section describes the physical, electrical and Environmental specifications for the various versions of Oracle Database Appliance.
This section describes the physical specifications for the various versions of Oracle Database Appliance.
Item | Oracle Database Appliance X6-2S | Oracle Database Appliance X6-2M | Oracle Database Appliance X6-2L | Oracle Database Appliance X6-2-HA |
---|---|---|---|---|
Height |
42.6 mm (1.7 in) |
42.6 mm (1.7 in) |
87.6 mm (3.5 in) |
42.6 mm (1.7 in) per server node 175 mm (6.9 in) per storage shelf |
Width |
436.5 mm (17.2 in) |
436.5 mm (17.2 in) |
445.0 mm (17.5 in) |
436.5 mm (17.2 in) per server node Storage shelf: 446.0 mm (17.6 in) |
Depth |
737.0 mm (29.0 in) |
737.0 mm (29.0 in) |
737.0 mm (29.0 in) |
737.0 mm (29.0 in) per server node Storage shelf: 558.0 mm (22.0 in) |
Weight |
16.1 kg (35.4 lbs) |
16.1 kg (35.4 lbs) |
29.0 kg (64.0 lbs) |
16.1 kg (34.5 lbs) per server node 38.0 kg (84.0 lbs) per storage shelf |
Item | Oracle Database Appliance Version 1 | Oracle Database Appliance X3-2/X4-2 | Oracle Database Appliance X5-2 |
---|---|---|---|
Height |
175.1 mm (6.9 in) |
42.6 mm (1.7 in) per server node 87.9 mm (3.5 in) per storage shelf |
42.6 mm (1.7 in) per server node 175 mm (6.9 in) per storage shelf |
Width |
437.0 mm (17.2 in) (without mounting ears) 482.6 mm (19 in) (with mounting ears) |
Server node: 436.5 mm (17.2 in) Storage shelf: 483.0 mm (19.0 in) |
Server node: 436.5 mm (17.2 in) Storage shelf: 483.0 mm (19.0 in) |
Depth |
762.0 mm (30.0 in) 782.0 mm (30.8 in) (including fan module handles and latches) |
Server node: 737.0 mm (29.0 in) Storage shelf: 630.0 mm (24.8 in) |
Server node: 737.0 mm (29.0 in) Storage shelf: 630.0 mm (24.8 in) |
Weight |
72.6 kg (160.0 lbs) |
16.3 kg (36.0 lbs) per server node 24.0 kg (52.9 lbs) per storage shelf |
16.3 kg (36.0 lbs) per server node 37.2 kg (82.0 lbs) per storage shelf |
This section describes the electrical specifications for the various versions of Oracle Database Appliance.
Item | Oracle Database Appliance X6-2S | Oracle Database Appliance X6-2M | Oracle Database Appliance X6-2L | Oracle Database Appliance X6-2-HA |
---|---|---|---|---|
Server node power supply output rated maximum |
600W at 100-127 VAC 600W at 200-240 VAC |
600W at 100-127 VAC 600W at 200-240 VAC |
1000W at 100-127 VAC 1000W at 200-240 VAC |
600W at 100-127 VAC 600W at 200-240 VAC |
Server node AC power |
7.2A at 100-127 VAC 3.4A at 200-240 VAC |
7.2A at 100-127 VAC 3.4A at 200-240 VAC |
8.5 -12A at 100-127 VAC 5.7A at 200-240 VAC |
7.2A at 100-127 VAC 3.4A at 200-240 VAC |
Storage shelf power supply output rated maximum |
Not included |
Not included |
Not included |
580W at 100-127 VAC 580W at 200-240 VAC |
Storage shelf AC Power |
Not included |
Not included |
Not included |
8A at 100-127 VAC 3A at 220-240 VAC |
Power usage |
For more information on power consumption, see Oracle Server X6-2 Power Calculator.
|
For more information on power consumption, see Oracle Server X6-2 Power Calculator.
|
For more information on power consumption, see Oracle Server X6-2L Power Calculator.
|
Server node
Storage shelf
|
Item | Oracle Database Appliance Version 1 | Oracle Database Appliance X3-2/X4-2 | Oracle Database Appliance X5-2 |
---|---|---|---|
Server node power supply output rated maximum |
1270W at 100-120 VAC 1370W at 200-240 VAC |
600W at 100-127 VAC 600W at 200-240 VAC |
600W at 100-127 VAC 600W at 200-240 VAC |
Server node AC power |
12A at 110-127 VAC 7A at 200-240 VAC 13A at 100 VAC (Japan only) |
7.2A at 100-127 VAC 3.4A at 200-240 VAC |
7.2A at 100-127 VAC 3.4A at 200-240 VAC |
Storage shelf power supply output rated maximum |
Not supported |
580W at 100-127 VAC 580W at 200-240 VAC |
580W at 100-127 VAC 580W at 200-240 VAC |
Storage shelf AC Power |
Not supported |
8A at 100-127 VAC 3A at 220-240 VAC |
8A at 100-127 VAC 3A at 220-240 VAC |
Power usage |
Not available |
Server node
Storage shelf
|
Server node
Storage shelf
|
This section describes the environmental specifications for a single, non-racked Oracle Database Appliance.
Item | Oracle Database Appliance X6-2S | Oracle Database Appliance X6-2M | Oracle Database Appliance X6-2L | Oracle Database Appliance X6-2-HA |
---|---|---|---|---|
Operating temperature |
5° C to 35° C (41° F to 95° F).
|
5° C to 35° C (41° F to 95° F)
|
5° C to 35° C (41° F to 95° F)
|
5° C to 35° C (41° F to 95° F)
|
Nonoperating temperature |
-40° C to 70° C (-40° F to 158° F).
|
-40° C to 70° C (-40° F to 158° F)
|
-40° C to 70° C (-40° F to 158° F)
|
-40° C to 70° C (-40° F to 158° F)
|
Operating humidity |
10% to 90% relative humidity, noncondensing |
10% to 90% relative humidity, noncondensing |
10% to 90% relative humidity, noncondensing |
10% to 90% relative humidity, noncondensing |
Nonoperating humidity |
Up to 93% relative humidity, noncondensing. |
Up to 93% relative humidity, non-condensing |
Up to 93% relative humidity, non-condensing |
Up to 93% relative humidity, non-condensing |
Operating altitude |
Up to 3,000 m* (9,840 ft); maximum ambient temperature is derated by 1° C per 300 m above 900 m * Except in China markets where regulations might limit installations to a maximum altitude of 2,000 m (6,560 ft). |
Up to 3,000 m* (9,840 ft); maximum ambient temperature is derated by 1° C per 300 m above 900 m * Except in China where regulations might limit installations to a maximum altitude of 2,000 m (6,560 ft). |
Up to 3,000 m* (9,840 ft); maximum ambient temperature is derated by 1° C per 300 m above 900 m * Except in China where regulations might limit installations to a maximum altitude of 2,000 m (6,560 ft). |
Up to 3,000 m* (9,840 ft); maximum ambient temperature is derated by 1° C per 300 m above 900 m * Except in China where regulations might limit installations to a maximum altitude of 2,000 m (6,560 ft). |
Nonoperating altitude |
Up to 12,000 m (39,370 ft) |
Up to 12,000 m (39,370 ft) |
Up to 12,000 m (39,370 ft) |
Up to 12,000 m (39,370 ft) |
Cooling |
For more information on power consumption, see Oracle Server X6-2 Power Calculator.
|
For more information on power consumption, see Oracle Server X6-2 Power Calculator.
|
For more information on power consumption, see Oracle Server X6-2L Power Calculator.
|
Server node
Storage shelf
|
Acoustic noise |
7.0 Bels A-weighted operating, 7.0 Bels A-weighted idling |
7.0 Bels A-weighted operating, 7.0 Bels A-weighted idling |
8.1 Bels A-weighted operating, 5.8 Bels A-weighted idling |
7.0 Bels A-weighted operating, 7.0 Bels A-weighted idling |
Item | Oracle Database Appliance Version 1 | Oracle Database Appliance X3-2/X4-2 | Oracle Database Appliance X5-2 |
---|---|---|---|
Operating temperature |
5° C to 35° C (41° F to 95° F).
|
5° C to 35° C (41° F to 95° F)
|
5° C to 35° C (41° F to 95° F)
|
Nonoperating temperature |
-40° C to 70° C (-40° F to 158° F).
|
-40° C to 70° C (-40° F to 158° F)
|
-40° C to 70° C (-40° F to 158° F)
|
Operating humidity |
10% to 90% relative humidity, noncondensing |
10% to 90% relative humidity, noncondensing |
10% to 90% relative humidity, noncondensing |
Nonoperating humidity |
Up to 93% relative humidity, noncondensing. |
Up to 93% relative humidity, non-condensing |
Up to 93% relative humidity, non-condensing |
Operating altitude |
Up to 3000 m* (9,840 ft). Maximum ambient temperature is derated by 1 oC per 300 m (984 ft) above 900 m (2,953 ft)
* Except in China markets where regulations might limit installations to a maximum altitude of 2,000 m (6,562 ft). |
Up to 3,048 m* (10,000 ft); maximum ambient temperature is derated by 1° C per 300 m above 900 m * Except in China where regulations might limit installations to a maximum altitude of 2,000 m (6,562 ft). |
Up to 3,048 m* (10,000 ft); maximum ambient temperature is derated by 1° C per 300 m above 900 m * Except in China where regulations might limit installations to a maximum altitude of 2,000 m (6,562 ft). |
Nonoperating altitude |
Up to 12,000 m (39,370 ft) |
Up to 12,000 m (39,370 ft) |
Up to 12,000 m (39,370 ft) |
Cooling |
Not available |
Server node
Storage shelf
|
Server node
Storage shelf
|
Acoustic noise |
7.8 B operating, 7.1 B idling (LwAd: 1 B=10 dB) |
7.9 B operating, 5.58 B idling (LwAd: 1 B=10 dB) |
7.0 Bels A-weighted operating, 7.0 Bels A-weighted idling |
For technical support, go to:
When requesting technical support for Oracle Database Appliance, report the following to Oracle Support Services:
Oracle Database Appliance Version 1 and Models X6-2S/X6-2M/X6-2L | Oracle Database Appliance X3-2/X4-2/X5-2 and X6-2-HA |
---|---|
For the Oracle Database Appliance Version 1 or Oracle Database Appliance X6-2S/X6-2M/X6-2L, report the serial number located on the front panel of the system, the top of the system, or on the Customer Information Sheet that is shipped with the system.
Note - You only need to extend the server node a couple of inches on its slide rails to see the serial label on the top of the system. You do not need to release any cables, or slide it to the extended maintenance position. |
For Oracle Database Appliance X3-2, Oracle Database Appliance X4-2, Oracle Database Appliance X5-2 and Oracle Database Appliance X6-2-HA, report the Top Level Identifier (TLI). To see the TLI, look on the Customer Information Sheet or look at the top of a server node or storage shelf on the left-hand side towards the front. The TLI part number and TLI serial number are the same for all factory-bundled components of an appliance. For example: If the appliance is in a rack where you cannot see the TLI, do one of the following:
|