70000 - Association Down

Alarm Group
vSTP
Description
Association down
Severity
Major
Instance
<AssocName>
HA Score
Normal
Auto Clear Seconds
0 (zero)
OID
vSTPVstpassociationDownNotify

Recovery

  1. If the association is manually disabled, then no further action is needed.
  2. Verify the association's local IP address and port number are configured on the remote ASP.
  3. Verify the association's remote IP address and port are correctly identify a remote ASP.
  4. Verify that IP network connectivity exists between the MP server and the remote ASP.
  5. Check the event history logs at Alarms & Events > View History for additional SS7 events or alarms from this MP server.
  6. Verify the remote ASP is not under maintenance.
  7. It is recommended to contact My Oracle Support (MOS) for assistance if needed