Go to primary content
Diameter Signaling Router Alarms and KPIs
Release 8.2
E89015-01
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

70001 - Link Down

Alarm Group
vSTP
Description
Link down
Severity
Minor
Instance
<LinkName>
HA Score
Normal
Auto Clear Seconds
0 (zero)
OID
vSTPLinkDownNotify

Recovery

  1. If the association hosting the link or the link itself is manually disabled, then no further action is needed.
  2. Verify alarm 70000 - Association Down is not raised for the association hosting the link. If the alarm is raised, refer to the recovery steps for that alarm.
  3. Verify RCs are configured properly at associated linkset.
  4. Check the event history logs at Alarms & Events > View History for additional SS7 events or alarms from this MP server.
  5. Verify that the remote ASP is not under maintenance.
  6. It is recommended to contact My Oracle Support (MOS) for assistance if needed