22728 - SBR Bindings Threshold Exceeded

Alarm Group:
SBR
Description:
The number of bindings threshold has been exceeded.
Severity:
Minor, Major, Critical
Instance:
<SbrDatabaseName>
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
eagleXgDiameterPSbrActBindThreshNotify

Recovery:

  1. The binding database specified in the Instance field is nearing the limit on the number of binding records. The alarm threshold percentages can be modified as desired by the network operator at the NOAM using Policy and Charging > Configuration > Alarm Settings.
  2. If a given alarm severity is unwanted, the alarm severity may be suppressed by checking the Suppress checkbox for that alarm severity.
  3. It is recommended to contact My Oracle Support (MOS) to discuss plans for system growth is this alarm continues to be asserted under normal operating conditions.

    Note:

    It is expected, but not guaranteed, that the system will continue to function beyond the tested maximum number of subscribers with bindings.