MTP3 Options elements

Table 3-11 describes the information on the SS7/Sigtran > Configuration > MTP3 Options page:

Table 3-11 MTP3 Options Elements

Element Description Data Input Notes
Timer T1 Changeover timer. This timer introduces a delay to help prevent message mis-sequencing on link changeover.

Format: Numeric

Range: 10 - 2000 msecs

Default: 60 msecs

Timer T3 Change-back timer. This timer introduces a delay to help prevent message mis-sequencing on link change-back.

Format: Numeric

Range: 10 - 2000 msecs

Default: 60 msecs

Timer T6 Controlled Rerouting timer. This timer introduces a delay to help prevent message mis-sequencing on controlled rerouting.

Format: Numeric Range: 10 - 2000 msecs

Default: 60 msecs

Timer T10 Destination Audit interval. This timer controls the interval at which RST/DAUD messages are sent when destination audit is activated. Destination audit is activated on receipt of a TFP/DUNA. If a TFA/DAVA is received, destination audit is deactivated.

Format: Numeric

Range: 1000 - 120000 msecs

Default: 60000 msecs

Timer T15 Destination Congestion Test Delay. This timer controls the length of the wait before starting the signaling route set congestion test.

Format: Numeric

Range: 100 - 10000 msecs

Default: 2000 msecs

Timer T16 Destination Congestion Test Timeout. This timer controls the length of the wait for the route set congestion status update.

Format: Numeric

Range: 100 - 10000 msecs

Default: 1000 msecs

SLS Rotation This value specifies whether the SLS rotation procedure is enabled for egress messages. If SLS rotation is Enabled, the SLS value of messages is rotated before routing the messages to network.

Format: List

Range: Disabled, Enabled

Default: Enabled