The Edit operation lets you add or remove the MTP Capability Point Code and the assigned Server Group from an LSP configuration, if the LSP is not referenced by a Link Set.
Click SS7/Sigtran > Configuration > Local Signaling Points.
Select the Local Signaling Point from the list and click Edit.
To delete an MTP Capability Point Code from the LSP, uncheck the checkbox.
A Capability Point Code cannot be removed from an LSP that is referenced by a Link Set. If necessary, perform Deleting a Link Set to remove the reference.
To add an MTP Capability Point Code, check the checkbox and enter the MTP Capability Point Code as described in Local Signaling Points elements.
To add a Server Group, click the name in the Unassigned Server Group list and click the (>>) arrows to add the Server Groups to the Server Groups included in this Local Signaling Point field. You can select more than one by pressing Ctrl while clicking a name and clicking the (>>) arrows to add the Server Groups to the Server Groups included in this Local Signaling Point field. Press Shift-click to select a range.
To remove a Server Group, click the name in the Server Groups included in this Local Signaling Point list and the (<<) arrows. You can select more than one by pressing Ctrl while clicking a name and clicking the (<<) arrows.
A Server Group cannot be removed from an LSP that is referenced by a Link Set. If appropriate, perform Deleting a Link Set.
Click OK, Apply, or Cancel.
If OK or Apply is clicked and any of the following conditions exists, an error message appears:
Any fields contain a value that is out of the allowed range
Any required field is empty (not entered)
Adding a Server Group would cause the maximum number of Server Groups per LSP (1) to be exceeded
The Local Signaling Point Name field value already exists
A Server Group added to the list of Server Groups no longer exists (has been deleted)
A Server Group added to the list of Server Groups does not have at least one Server assigned to it
The MTP True Point Code was already assigned to another LSP (by another user)
The MTP Capability Point Code already exists as an MTP True Point Code
The MTP Capability Point Code already exists as an MTP Capability Point Code for this LSP
Any of the MTP Capability Point Code check boxes is checked, but the corresponding MTP Capability Point Code value was not entered
Adding this Local Signaling Point would cause the maximum number of Local Signaling Points per site (10) to be exceeded