Verify that the library firmware meets or exceeds the minimum requirements. If it does not, submit a service request to Oracle Support to upgrade the firmware.
See Library Requirements for minimum firmware versions.
On the Library CLI (SL500, SL3000, and SL85000)
Execute the following command:
version print
If the screen displays SYNTAX ERROR!!
, the library firmware is down-level. Contact Oracle Support to upgrade the firmware
On SLC (SL500, SL3000, and SL85000)
In the Tools menu, select System Detail.
In the navigation tree, select Library.
Select the Properties tab, then select the Library Controller tab.
On the Browser Interface (SL150 only)
In the navigation tree, select Firmware.
The firmware version is displayed under the Library Firmware section. Alternately, you can click the About button in the status bar to obtain the firmware version.