25510 - Multiple DA-MP Leader Detected Alarm

Alarm Group:
DIAM
Description:
This alarm occurs when multiple active DA-MP leaders have been detected.
Severity:
Critical
Instance:
<NetworkElement>
HA Score:
Normal
Auto Clear Seconds:
0 (zero)
OID:
eagleXgDiameterMultipleDaMpLeadersDetectedNotify
Cause:
The alarm #25510 raises:
  • When more than one DA-MP report themselves as Leader.
  • When DSR process is running on all DA-MPs and ComAgent Connection is down between two or more DA-MP's.
The alarm clears when maintenance leader reports a single active DA-MP leader.
Diagnostic Information:
  • This alarm is raised against the Network Element when multiple DA-MPs report themselves as Leader.
  • Examine the alarm log from Main Menu > Alarms & Events on Active SOAM Server.
  • When this alarm is raised Existing IPFE Connection, Route List, and Peer Node alarms will be cleared.
  • New IPFE Connection, Route List, and Peer Node alarms are suppressed.

Recovery:

  1. Verify the MP operational status of the DA-MP from the Diameter > Maintenance > DA-MP active SOAM screen.
    1. Verify the # Peer MPs Unavailable column displays 0 for each DA-MP server.
    2. Verify all DA-MP servers are available in individual DA-MP server tabs on the Diameter > Maintenance > DA-MP active SOAM screen.
    3. Verify ComAgent inter-MP connections (auto) are in the InService state on the Communication Agent > Maintenance > Connection Status screen.
  2. If the problem persists, it is recommended to contact My Oracle Support for assistance.