19227 - Received unsolicited ASP-DOWN-ACK
- Event Type:
- SS7
- Description:
- The adjacent
server
at the specified IP address and port has sent an ASP-DOWN-ACK, but not in
response to an ASP-DOWN message from the MP
server.
Normally this indicates that the far-end of the association is being taken down
for maintenance. If the association administrative state is
Enabled, the MP
server
automatically attempts to bring the association back to ASP-UP. This is done by
sending an ASP-UP. The MP
server
continues to send ASP-UP until an ASP-UP-ACK is received, the SCTP association
comes down, or the association administrative state is changed to
Blocked or
Disabled.
- Severity:
- Info
- Instance:
- <AssocName>
- HA Score:
- Normal
- Throttle Seconds:
- 30
- OID:
- awpss7ReceivedUnsolicitedAspDownAckNotify
Recovery:
-
Verify that the adjacent
server
on the
Signaling Gateway is not under maintenance.
-
If the problem persists, it is recommended to
contact My Oracle Support.