70008 - Linkset Restricted

Alarm Group
vSTP
Description
The SS7 linkset to an adjacent SP has restricted.
Severity
Major
Instance
<LinksetName>
HA Score
Normal
Auto Clear Seconds
N/A
OID
vSTPMtp3LinksetRestrictedNotify

Recovery

  1. Monitor the route status at SS7/SIGTRAN > Maintenance > Remote Signaling Points.
  2. Verify that IP network connectivity exists between the MP server and the adjacent servers.
  3. Check the event history logs at Alarms & Events > View History for additional SS7 events or alarms from this MP server.
  4. Verify that the adjacent server is not under maintenance.
  5. It is recommended to contact My Oracle Support for assistance if needed.