Go to primary content
Oracle® Communications Diameter Signaling Router Measurements
Release 8.3
E93201
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

RxFabrNgnPsDrop

Measurement ID
10672
Measurement Group
Full Address Resolution Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of FABR ingress NGN-PS messages discarded or rejected.
Collection Interval
5 min
Peg Condition
Each time NGN-PS Diameter message is dropped due these conditions:
  • In scenarios where the configured action is 'Discard'
    • where address resolution is unsuccessful
    • Event sending to ComAgent is unsuccessful
    • Delivery failure notification from
  • Event sending failure to DRL.
Measurement Scope
Server Group

Recovery

  1. When non-zero, examine other failure measurements (RxFabrUnkApplId, RxFabrDecodeFailureResol, RxFabrResolFailAll, RxFabrResolFailCmdcode, RxFabrResolFailNoAddrAvps, TxFabrDbConFail, TxFabrAbandonRequest, RxFabrInvalidImsiMcc, RxFabrBlacklistedImsi, RxFabrBlacklistedMsisdn) to isolate reasons for failures.
  2. It is recommended to contact My Oracle Support (MOS) for assistance.