RxFabrInvalidImsiMcc
- Measurement ID
- 10657
- Measurement Group
- Full Address Resolution Exception
- Measurement Type
- Simple
- Measurement Dimension
- Single
- Description
- The number of times an AVP instance present in a Diameter request message is rejected due to the MCC contained in the decoded IMSI falling within one of the configured Reserved MCC Ranges.
- Collection Interval
- 5 min
- Peg Condition
- Each time a Diameter request message is rejected due to the MCC contained in the decoded IMSI falling within one of the configured Reserved MCC Ranges.
- Measurement Scope
- Server Group
Recovery
- Validate the ranges configured in the Reserved MCC Ranges table.
- Verify that the MCC portion of the decodable IMSI received by RBAR does not fall within the configured Reserved MCC Ranges.
- If the problem persists, it is recommended to contact My Oracle Support (MOS).