Go to primary content
Oracle® Communications Diameter Signaling Router Measurements
Release 8.3
E93201
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

RxFabrInvalidImsiMcc

Measurement ID
10657
Measurement Group
Full Address Resolution Exception
Measurement Type
Simple
Measurement Dimension
Single
Description
The number of times an AVP instance present in a Diameter request message is rejected due to the MCC contained in the decoded IMSI falling within one of the configured Reserved MCC Ranges.
Collection Interval
5 min
Peg Condition
Each time a Diameter request message is rejected due to the MCC contained in the decoded IMSI falling within one of the configured Reserved MCC Ranges.
Measurement Scope
Server Group

Recovery

  1. Validate the ranges configured in the Reserved MCC Ranges table.
  2. Verify that the MCC portion of the decodable IMSI received by RBAR does not fall within the configured Reserved MCC Ranges.
  3. If the problem persists, it is recommended to contact My Oracle Support (MOS).