TxNiddT8DlDataPostFailure
- Measurement ID
- 13018
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed on SCS Application Server
- Description
- The number of T8 NIDD new Downlink Data requests for which a
failure was returned by SCEF application in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented each time an HTTP POST request
message with NIDD Downlink Data Delivery resource is responded with a non-2xx
response code by SCEF application.
- Measurement Scope
- Network Element, Place Association
Recovery
-
The response message may contain an application/problem+json body
describing the details of the problem encountered that failed the request.
Possible causes may be:
- The requested NIDD configuration (identifier by the SCS
Application Server ID and the TLTRI) was not found in the SCEF database.
- A PDN connection is not available to deliver the downlink
data and the PDN Establishment Option is disabled or set to INDICATE_ERROR by
the SCS Application Server.
- The UE is not available and the Data Buffering option is
disabled or not requested by the SCS Application Server.
- The data packet size exceeds the maximum bufferable packet
size.
- The data needs to be buffered but the UE’s downlink data
queue is full.
- The data needs to be buffered but the packet size exceeds
the maximum bufferable packet size.
- The Downlink APN Rate limit has been reached.
- The Serving PLMN Rate limit has been reached.