TxNiddT8DlDataPutFailure
- Measurement ID
- 13021
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed on SCS Application Server
- Description
- The number of T8 NIDD Downlink Data update requests for which a
failure was returned by SCEF application in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented each time an HTTP PUT request
message with an Individual NIDD Downlink Data Delivery resource is responded
with a non-2xx response code by SCEF application.
- Measurement Scope
- Network Element, Place Association
Recovery
-
The response message may contain an application/problem+json body
describing the details of the problem encountered that failed the request.
Possible causes may be:
- The requested NIDD configuration (identifier by the SCS
Application Server ID and the TLTRI) was not found in the SCEF database.
- The requested Downlink Data Delivery packet (identified by
the TTRI) was not found in the UE's buffered packets queue.
- A PDN connection is not available to deliver the downlink
data and the PDN Establishment Option is disabled or set to
INDICATE_ERROR by the SCS Application Server.
- The UE is not available and the Data Buffering option is
disabled or not requested by the SCS Application Server.
- The data packet size exceeds the maximum bufferable packet
size.