TxNiddT8DlDataPutFailure

Measurement ID
13021
Measurement Group
SCEF NIDD Exception
Measurement Type
Simple
Measurement Dimension
Arrayed on SCS Application Server
Description
The number of T8 NIDD Downlink Data update requests for which a failure was returned by SCEF application in the given collection interval.
Collection Interval
30 min
Peg Condition
This measurement is incremented each time an HTTP PUT request message with an Individual NIDD Downlink Data Delivery resource is responded with a non-2xx response code by SCEF application.
Measurement Scope
Network Element, Place Association

Recovery

  1. The response message may contain an application/problem+json body describing the details of the problem encountered that failed the request. Possible causes may be:
    • The requested NIDD configuration (identifier by the SCS Application Server ID and the TLTRI) was not found in the SCEF database.
    • The requested Downlink Data Delivery packet (identified by the TTRI) was not found in the UE's buffered packets queue.
    • A PDN connection is not available to deliver the downlink data and the PDN Establishment Option is disabled or set to INDICATE_ERROR by the SCS Application Server.
    • The UE is not available and the Data Buffering option is disabled or not requested by the SCS Application Server.
    • The data packet size exceeds the maximum bufferable packet size.