TxNiddT8DlDataGetFailure
- Measurement ID
- 13024
- Measurement Group
- SCEF NIDD Exception
- Measurement Type
- Simple
- Measurement Dimension
- Arrayed on SCS Application Server
- Description
- The number of T8 NIDD Individual Downlink Data queries for which
a failure was returned by SCEF application in the given collection interval.
- Collection Interval
- 30 min
- Peg Condition
- This measurement is incremented each time an HTTP GET request
message with an Individual NIDD Downlink Data Delivery resource is responded
with a non-2xx response code by SCEF application.
- Measurement Scope
- Network Element, Place Association
Recovery
-
The response message may contain an application/problem+json body
describing the details of the problem encountered that failed the request.
Possible causes may be:
- The requested
NIDD configuration (identifier by the SCS Application Server ID and the TLTRI)
was not found in the SCEF database.
- The requested
Downlink Data Delivery packet (identified by the TTRI) was not found in the
UE's buffered packets queue.