Error Code 2xx/3xx
- Associated Error Category
- Binding Found But Unable To Route
- Description
- Request message is received and a binding with a PRCF was found. Policy DRA can't route the request to PCRF due to PCRF being unreachable.
- Associated P-DRA Alarm/Event
- Event 22707 - Diameter Message Processing Failure (refer to the DSR Alarms and KPIs Reference for details about this event)
- Associated Measurement
- TxPdraAnswersGeneratedForDiameterErr
- Associated Diameter Interface / Message Type
- Gx/Gxx CCR-I
- Rx AAR
- Gx-Prime CCR-I
- GUI Configurable
- Yes
Recovery
- Error code 2xx/3xx is generated by DSR routing layer for various routing errors that result in the failure of routing the Diameter request to the PCRF.
- Go to the PCA NOAM GUI to check the server status from to verify if some DA-MPs have failed (if some servers on the same side fail, the traffic will be distributed amongst the remaining DA-MPs).
- Go to to check the ingress traffic rates of the DA-MPs. Each DA-MP in the site should have about the same ingress rate in normal situation
- Go to to search for relevant congestion alarms. The Display Filter may be set as Timestamp or Server to include Policy DRA, DRL, or DCL alarms.
- Check the PCA SOAM GUI to search for relevant measurements.