Go to primary content
Oracle® Communications Diameter Signaling Router Measurements
Release 8.3
E93201
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

Error Code 510

Associated Error Category
Binding Found But Unable To Route
Description
A slave session could not be routed because, on polling the slave, sessionRef was no longer in the binding database.
Associated P-DRA Alarm/Event
N/A
Associated Measurement
SbrSlavePollingFail
Associated Diameter Interface / Message Type
  • Gx/Gxx CCR-I
  • Rx AAR
  • Gx-Prime CCR-I
GUI Configurable
Yes

Recovery

  1. See Early binding Processing with PCRF Pool in the Error Resolution appendix of the Policy and Charging Application User Guide to investigate and understand
  2. Go to the PCA SOAM GUI at Main Menu > Status & Manage > Server to check binding SBRs' status.
  3. Go to the Main Menu > Alarms & Events > View History to check binding SBR's congestion alarm/event info to determine a relation with the error.
  4. Go to the PCA SOAM GUI Main Menu > Measurements > Report to search for relevant measurements. Select, but not limited to, "SBR Binding Exception" Measurement Group for the measurements directly related to this error.