The Bay Hardware tab elements provide index cards with data for the following areas:
Entity Summary
Entity Summary includes standard information, if applicable, including Entity Type, Enclosure, Bay and Hot-swap State.
Table 5-18 Elements in the Entity Summary Index Card
Element | Description |
---|---|
Entity Type | The Onboard Administrator, server blade, switch, SAN switch, or storage blade that resides in the bay. |
Enclosure | The enclosure ID. |
Bay | The bay location: 0AR or 1 - 16F or R. Note that PMAC appends a character to the bay location to indicate the orientation (F for front and R for rear). An example is 1F, which represents bay 1 on the front of the enclosure. |
Hot-swap State | One of the following hardware states as defined in the HPI
specification for an entity in the system:
|
Product Area
Product Area information is automatically discovered by PMAC.
Table 5-19 Elements in the Product Area Index Card
Element | Description |
---|---|
Manufacturer | The name of the manufacturer of the product as reported from the product's FRU information. The product manufacturer may differ from the board manufacturer if the part is being integrated into a larger product offering. |
Product Name | The name of the product as assigned by the product manufacturer. |
Part Number | The product part number as assigned by the product manufacturer. |
Product Version | The product version number as assigned by the product manufacturer. |
Serial Number | The serial number assigned by the product manufacturer. The serial number uniquely identifies this product to the product manufacturer. |
Asset Tag | The asset tag assigned to the product by the product manufacturer. |
File ID | Optional field for the use of the product manufacturer. |
Board Area
Board Area information is automatically discovered by PMAC.
Table 5-20 Elements in the Board Area Index Card
Element | Description |
---|---|
Mfg Date/Time | The date and time when the component was manufactured, represented by the number of seconds since 00:00:00, January 1, 1970, Coordinated Universal Time (UTC). |
Manufacturer | The name of the manufacturer of the component as reported from the component's FRU information. Examples of components are a board, a fan tray, and a power supply. |
Product Name | The name of the component as assigned by the component manufacturer. |
Part Number | The component part number as assigned by the component manufacturer. |
Serial Number | The serial number assigned by the component manufacturer. The serial number uniquely identifies this product to the component manufacturer. |
File ID | Optional field for the use of the component manufacturer. |
Partner Device
Partner Device information is automatically discovered by PMAC.
Note:
This index card is only displayed for storage blades, PCI expansion blades, and their partner blades.Table 5-21 Elements in the Partner Device Index Card
Element | Description |
---|---|
Name | The name of the partner device. |
Bay | The bay identifier of the partner device. This identifier is also a hyperlink that can be used to display the hardware page of the partner device. |
Chassis Area
Chassis Area information is automatically discovered by PMAC.
Table 5-22 Elements in the Chassis Area Index Card
Element | Description |
---|---|
Part Number | The part number assigned to the chassis as reported from the chassis's FRU information. |
Serial Number | The serial number assigned to the chassis as reported from the chassis's FRU information. |