Adding an IPGWx Card
This procedure is used to add an IPGWx card to the
database using the
ent-card
command. An IPGWx card is a
card that is running either the SS7IPGW or IPGWI applications.
Table 4-1shows
the cards that can be provisioned in this procedure.
Table 4-1 IPGWx Card Types
Card Type | Part Number |
---|---|
E5-ENET | 870-2212-xx |
E5-ENET-B | 870-2971-xx |
The EAGLE can support a combination of E5-ENET and E5-ENET-B cards.
The
ent-card
command uses these parameters.
:loc
– The location of
the card being added to the database.
:type
– The type of card
being added to the database. For this procedure, the value of this parameter is
dcm
.
:appl
– The application
software that is assigned to the card. For this procedure, the value of this
parameter is
ss7ipgw
for ANSI IP network
connections or
ipgwi
for ITU IP network connections.
:force
– If the global
title translation feature is on, the
force=yes
parameter allows the LIM to
be added to the database even if the current SCCP transactions-per-second
threshold is unable to support the additional SCCP transaction-per-second
capacity created by adding the IP card. This parameter is obsolete and is no
longer used.
If you have purchased the ISUP-over-IP (ipisup
)
feature, verify that the ISUP-over-IP feature is turned on (ipisup=on
) using the rtrv-feat
command. If the appropriate feature is off, turn it on with the chg-feat
command. For more information on the
ISUP-over-IP feature, refer to section Point-to-Multipoint Connectivity (SS7IPGW and IPGWI).
Note:
Before turning on the ISUP-over-IP feature (ipisup
), make sure you have purchased this feature. If
you are not sure whether you have purchased the ISUP-over-IP feature, contact
your Oracle Sales Representative or Account Representative. Once a feature has
been turned on with the
chg-feat
command, the feature cannot be
turned off.
Card Slot Selection
The E5-ENET card can be inserted into any card slot, except for card slots that must remain empty to accommodate dual-slot cards, slots 09 and 10 in each shelf, and slots 1113 through 1118.
To provision a E5-ENET card, the shelf containing the
E5-ENET card must have HIPR2 cards installed in slots 9 and 10 in that shelf.
If HIPR2 cards are not installed in the shelf that the E5-ENET card will
occupy, the E5-ENET card will be auto-inhibited when the E5-ENET card is
inserted into the shelf. Enter the
rept-stat-gpl:gpl=hipr2
command to
verify whether or not HIPR2 cards are installed in the same shelf as the
E5-ENET card being provisioned in this procedure.
Figure 4-1 Add an IPGWx Card - Sheet 1 of 3
Note:
Before executing this procedure, make sure you have purchased the ISUP-over-IP feature. If you are not sure whether you have purchased the ISUP-over-IP feature, contact your Sales Representative or Account Representative.Figure 4-2 Add an IPGWx Card - Sheet 2 of 3
Figure 4-3 Add an IPGWx Card - Sheet 3 of 3