Introduction to Measurements

This section describes EAGLE measurements. Measurements provide support for:

Measurements provide operations and maintenance personnel with network performance and STP performance data in accordance with:

Measurements can be collected and reported with the following collection methods:
The primary functions of Measurements are as follows:
  • Collection

    Measurements are collected in 5-minute, 30-minute, and 60-minute intervals. An option exists for the default 30-minute measurements to be collected every 15 minutes. Many 30-minute measurements intervals are accumulated into daily intervals.

  • Storage

    Measurements are stored in dedicated RAM tables and/or disks after collection. Most are retained for 24 hours. Measurements for some features are retained for 7 days.

  • Retrieval

    Measurements data is retrieved from the RAM storage area and/or disk. ACTIVE measurement data is retrieved and reported from the application cards except for SCP SMCs. Registers collected from SCP SMCs are not supported for ACTIVE measurements and will be reported as zero in an ACTIVE measurement report. An ACTIVE linkset report requires all links in the linkset to be available in order to provide the report.

  • Reporting

    Measurement reports are available on-demand/scheduled as shown in Table 2-1.

    Table 2-1 Demand and Scheduled Reporting

    Reporting Interval Measurements Platform E5-OAM Integrated Measurements
    Demand Scheduled Demand Scheduled

    5-minute

    Yes

    Yes

    Yes

    Yes

    15-minute (optional)

    Yes

    Yes

    Yes

    Yes

    30-minute

    Yes

    Yes

    Yes

    Yes

    Day-to-hour

    Yes

    No

    Yes

    No

    Hourly

    Yes

    Yes

    Yes

    Yes

    Daily

    Yes

    Yes

    Yes

    Yes

    Scheduled measurements are directed to the Traffic Unsolicited Output Message group. No other unsolicited output is sent to this output group.

Note that the collection of measurements is a separate task from reporting. Measurements collection is activated automatically upon system power-up, or through administrative commands. Collection is organized by ENTTYPE and reporting period. Collection occurs per link every 5 minutes, and separately every 30 minutes. Measurements are generated on the application cards and periodically collected by the UI and stored for later retrieval, unless the Measurements Platform is enabled, whereas the information is collected and stored by the dedicated MPCM cards.

Refer to the Commands User's Guide for descriptions of commands used to generate, schedule, and transfer measurements reports.