How to calculate transaction units per second (TPS)

TPS can be calculated for IPGW, IPLIM, and IPSG cards. If E5-ENET-B cards are used as IPSG cards, then the TPS is calculated depending on whether the E5-ENET-B IPSG High Throughput feature is ON or OFF.

Calculating TPS for IPGW and IPLIM Cards

Refer to Table 5-12 to follow the process.

  1. Determine which application will carry the traffic (IPGWx, IPLIMx).
  2. Determine the adapter protocol type of the association(s) that will carry the traffic. For IPGW and IPLIM cards the adapter is always M3UA.
  3. Determine how many distinct categories of traffic will be carried by the card. Characteristics that distinguish categories include:
    • Average SIF size
    • Whether or not the traffic is monitored (all rows have monitoring by E5IS)
    • How many connections per card will carry the traffic (2)
    • Whether Signal Transfer Point SLAN or SCCP Conversion is applied to the traffic (3)

    Distinct traffic categories are identified by rows (A, B).

  4. Select the TU value that applies to each distinct category of traffic (6)
  5. If the total bi-directional MSU rate of each category ((A7), (B7)) is known in advance, then the:
    • Total TU rate for a category = MSU rate x TU value ((A7) x (A6))
    • Total TU rate to be carried by the card = Sum of all TU rates of the traffic categories ((A6) x (A7) + (B6) x (B7))

    Then compare that value to the Base Card Capacity (7).

  6. If the fraction of total traffic that applies to each category is known, then the maximum total MSU rate, that is, the actual Advertised Capacity, can be determined by dividing the Base Advertised Capacity (7) by the total TU value of the traffic mix (6).

Table 5-12 Calculating TPS for IPGW and IPLIM Cards

  1 MSU SIF Size 2 # of Open Conns (1) 3 SLAN and/or SCCP Conver- sion 4 Base TU 5 Adjust- ment 6 Total TU 7 Max MSU/s 2000 Max MSU/s 4000 Max MSU/s 5000(2)
A 0..140 <=8 No 1.0 0.43 1.43 1400 2800 3500
0..140 <=8 Yes 1.0 0.67 1.67 1200 2400 3000
0..140 >8 No 1.0 0.82 1.82 1100 2200 2750
0..140 >8 Yes 1.0 1.00 2.00 1000 2000 2500
141..272 <=8 No 1.43 0.80 2.23 900 1800 2250
B 141..272 <=8 Yes 1.43 1.24 2.67 750 1500 1875
141..272 >8 No 1.43 1.65 3.08 650 1300 1620
141..272 >8 Yes 1.43 1.91 3.34 600 1200 1500

Footnote 1 Open Connections and Active SLKs are not always synonymous, depending on the GPL. For IPLIM, one SLK equals one connection. For IPGW, one SLK can equal up to 50 connections. For IPSG, one connection equals at least one SLK.

Footnote 2 E5IS Data Feed refers to STC-style monitoring. Fast Copy does support Large MSUs and has a zero transaction unit cost.

Calculating TPS for IPSG Cards: E5-ENET-B when IPSG High Throughput Feature OFF, E5-ENET

Refer to Table 5-13 to follow the process:

  1. Determine whether an E5-ENET or E5-ENET-B card is used.
  2. Determine the adapter protocol type of the association(s) that will carry the traffic .
  3. Determine how many distinct categories of traffic will be carried by the card. Characteristics that distinguish categories include:
    • Average SIF size (1)
    • Whether or not traffic is monitored
    • How many connections per card will carry the traffic (2)
    • Whether Signal Transfer Point SLAN or SCCP Conversion applies to the traffic (4)
    • Whether the MSU is copied by E5IS Data Feed (5)

    Distinct traffic categories are identified by rows (A, B)

  4. Select the TU value that applies (7).
  5. The maximum total MSU rate, (actual Advertised Capacity), can be determined by dividing the Max MSU/s for the card by the total TU (7).

Table 5-13 Calculating TPS for IPSG Cards: E5-ENET-B when IPSG High Throughput Feature OFF, E5-ENET

  1MSU SIF Size 2Number of links 3Protocol 4MSU Triggers SLAN or SCCP copy 5MSU Copied by E5IS Data Feed 6 TU Adjust- ment Factor 7Total TU 8Max MSU/s 5000 (E5- ENET) 9Max MSU/s 6500 (E5- ENET-B)
A 0..160 <=16 M2PA No No 0 1.0 5000 6500
  0..160 <=16 M3UA No No 0 1.0 5000 6500
  0..160 <=16 M2PA Yes No 0.00143 * MSU Size 1 + (0.00143 * MSU Size) -- (MSU size dependent) 5687
  0..160 <=16 M3UA Yes No 0.00143 * MSU Size 1 + (0.00143 * MSU Size) -- (MSU size dependent) 5687
  0..160 <=16 M2PA No Yes 0.43 1.43 3496 4545
  0..160 <=16 M3UA No Yes 0.43 1.43 3496 4545
  0..160 >16 M2PA No No 0.135 1.135 4405 5727
  0..160 >16 M3UA No No 0.135 1.135 4405 5727
B 161..272 <=16 M2PA No No 0.15 1.15 4348 5652
  161..272 <=16 M3UA No No 0.15 1.15 4348 5652
  161..272 <=16 M2PA Yes No 0.00143 * MSU Size 1 + (0.00143 * MSU Size) -- (MSU size dependent) 5687
  161..272 <=16 M3UA Yes No 0.00143 * MSU Size 1 + (0.00143 * MSU Size) -- (MSU size dependent) 5687
  161..272 <=16 M2PA No Yes 0.43 1.43 3496 4545
  161..272 <=16 M3UA No Yes 0.43 1.43 3496 4545
  161..272 >16 M2PA No No 0.15 1.15 4348 5652
  161..272 >16 M3UA No No 0.15 1.15 4348 5652

Calcuating TPS for IPSG Cards: E5-ENET-B IPSG High Throughput Feature ON

Refer to Table 5-14 to follow the process for an IPSG card when the E5-ENET-B IPSG High Throughput feature is turned on.

  1. Determine whether the card meets the standards shown in Table 5-5. If the card does not meet the optimized configuration, determine whether the card is being de-rated.
  2. Determine the adapter protocol type of the association(s) that will carry the traffic (4).
  3. Select the TU value that applies (6).
  4. The maximum total MSU rate, (actual Advertised Capacity), can be determined by dividing the Max MSU/s for the card by the total TU (6).

Table 5-14 Calculating TPS for E5-ENET-B IPSG Cards: E5-ENET-B IPSG High Throughput Feature ON

1 Avg MSU SIF size (excluding large MSUs) 2Association Round Trip Time RTT (ms) 3Number of Links 4Protocol 5TU Adjust- ment Factor 6Total TU 8Max MSU/s 5000 (E5- ENET) 7Max MSU/s 9500(E5- ENET-B)
0..120 <=50 <=4 M2PA 0 1.0 5000 9500
0..120 <=50 <=4 M3UA 0.05 1.05 5000 9048
160 <=50 <=4 M2PA 0.048 1.048 5000 9065
1..120 70 <=4 M3UA 0.13 1.13 5000 8407
1..120 <=50 8 M2PA 0.025 1.025 5000 9268
150 90 16 M3UA 0.281 1.281 5000 7416