0517 - Degraded Mode - Multiple Cards Failed

The Measurements Platform subsystem is degraded because more than one MCPM card is out of service. The Measurements Platform subsystem can successfully complete all of its work, but may have no spare MCPM.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
** 0100.0517 ** MEAS SYSTEM    Degraded Mode - multiple cards failed

Alarm Level: Major

Recovery

  1. Enter the following command to determine the status of the MCPM cards:
    rept-stat-meas
  2. Reinitialize the faulty card using the command.
    init-card
  3. If the fault has not cleared, reseat the faulty card.
  4. If the fault has not cleared, replace the faulty MCPM card.
  5. Repeat 2 through 4 for each faulty MCPM card.
    Refer to the Maintenance Manual for card removal/replacement procedures.