0619 - SIP SYSTEM is Not Available
This alarm indicates SIP feature is not ON and System has no SIP card that is Active/IS-NR.
Example 
                     		  
 
                  		
                  1         2         3         4         5         6         7         8
12345678901234567890123456789012345678901234567890123456789012345678901234567890   
*C  0002.0619 *C SIP SYSTEM             SIP System is not availableAlarm Level: Critical
Recovery
- Enter the following command to verify the status and
			 location of the SIP card: 
			 rept-stat-sip.
- Enter the following command to move the SIP card to
			 an ACTIVE status if loading is successful: 
			 rst-card:loc=xxxwhere xxxx is the location of the SIP card identified in 1.
- Enter the following command to verify the status and
			 location of the SIP card: 
			 rept-stat-sip.
- Verify the SIP card reset in 2 are ACTIVE/IS-NR.
- If the SIP card remains INACTIVE, replace the card. Refer to the Maintenance Manual for card removal/replacement procedures.