Recovery Procedure for a Non-MASP Card

Caution:

Resetting, reseating, or replacing a LIM will cause both links on the card to fail. If the card is a LIM, place the links on the LIM out of service by entering the dact-slk command.
  1. Wait five minutes to see if the card corrects itself.
  2. If the problem persists, enter the following command to retrieve the terminal types and port numbers:
    rtrv-trm
  3. Enter the following command to inhibit each OAP terminal displayed in the output from 2.
    inh-trm:trm=x
    where x is the port number.

    Note:

    The force parameter is required for the last OAP terminal inhibited.
  4. Enter the following command to reinitialize the indicated card and force the card to load the current level of database.
    init-card:loc=x

    where x is the card location stenciled on the shelf of the system.