Siebel Data Quality Administration Guide > Configuring Data Quality > Process of Configuring Data Synchronization Between Siebel and Oracle Data Quality Matching Server >

Configuring Object Managers for ISS Data Source


Use the following procedure to configure object managers for the ISS Data Source. This task is a step in Process of Configuring Data Synchronization Between Siebel and Oracle Data Quality Matching Server.

To configure object managers for ISS Data Source

  1. Navigate to Administration - Server Configuration, Enterprises, and then Component Definitions view.
  2. Query for the components used with UCM, such as, the following:
    • EAI
    • UCM
    • Data Quality
    • Workflow
  3. Select a component, and then select Start Reconfiguration from the main menu.
  4. In the lower applet, query for the following parameter: OM - Named Data Source.

    NOTE:  The value for this parameter is similar to the following: ServerDataSrc,GatewayDataSrc.

  5. Add a comma after the last data source, then add the ISS data source you created in Configuring the Data Source. The default data source name is ISSDataSrc.
  6. Save the record, then select Commit Reconfiguration from the main menu.
  7. Repeat Step 3 through Step 6 for all required Object Managers.

    For example, add ISSDataSrc to the following components:

    • EAI Object Manager: OM - Named Data Source name
    • UCM Object Manager: OM - Named Data Source name
    • UCM Batch Manager: OM - Named Data Source name
    • Data Quality Manager
    • Workflow Process Batch Manager
    • Workflow Process Manager
  8. Click Synchronize to save the changes to the Gateway Configuration file.
  9. Start the Gateway Server and the Siebel Server.
Siebel Data Quality Administration Guide Copyright © 2018, Oracle and/or its affiliates. All rights reserved. Legal Notices.