| Oracle® Communications EAGLE Commands Error Recovery Reference Release 46.7 E97329 Revision 1 |
|
![]() Previous |
![]() Next |
If the data=persist parameter is specified, and if all of the specified cards do not meet the warm restart requirements, then the force parameter must be specified and a full data download may be required. Table 2-6 describes the possible reasons a card may require a full data download:
Table 2-6 Reason that Card Requires a Full Data Download
| xxxxxxxx value | Description |
|---|---|
| POWER ON | Power on reset |
| XILINX VERSION | M256 Xilinx version has changed |
| DB VERSION | LNP Database version has changed |
| DB LEVEL | Database level is not supported or difference exceeds incremental loading capability |
| DB STATUS | Database status is incoherent |
| HW ERR | Hardware error bit checks on the card fail |
| AUDIT FAILED | Checksum comparisons of the LNP database fail |
| AUDIT TIMEOUT | LNP initialization audit timed out |
| NO AUDIT | Unable to perform LNP DB audit. LNP audit not on or excessive number of unknown checksums |
| USER REQUEST | User initiated init-card or init-sys command reload type cold |
| UNKNOWN | Unknown |
| OTHER | Other |
Recovery
Re-enter the init-card or init-sys command that generated this error message, specifying a valid combination of parameters. Refer to the command description in the Commands User's Guide for assistance.
Contact My Oracle Support if this error message appears again. My Oracle Support (MOS).