| Oracle® Communications EAGLE Database Administration - SS7 User's Guide Release 46.7 E97335 Revision 1 |
|
![]() Previous |
![]() Next |
This procedure is used to change the
values of a level 2 timer set using the
chg-l2t command.
The
l2tset parameter specifies the
level 2 timer set that is being changed. The
EAGLE contains
35 level 2 timer sets that signaling links can
be assigned to. Level 2 timer sets are assigned to different types of signaling
links as shown in
Table 3-16.
Table 3-16 Level 2 Timer Sets
| Level 2 Timer Set (l2tset Parameter Value) | Default Level 2 Timer Set Value for Signaling Links | Type of Signaling Link |
|---|---|---|
|
1 - 10 |
1 |
Low-speed ANSI signaling links |
|
11 - 20 |
11 |
Low-speed ITU signaling links |
|
21 - 25 |
21 |
ITU-N high-speed signaling links for China |
|
26 - 30 |
26 |
ITU-N high-speed signaling links for areas other than China |
| 31 - 35 |
31 |
Unchannelized T1 high-speed signaling links |
Table 3-17 Level 2 Timer Values - Low-Speed ANSI Signaling Links
| Level 2 Timers | Level 2 Timer Sets 1 - 10 (in milliseconds) |
|---|---|
|
Timer 1 – Aligned ready ( |
5000 - 20000 System Default - 13000 |
|
Timer 2 – Not aligned ( |
5000 - 30000 System Default - 11500 |
|
Timer 3 – Aligned ( |
5000 - 20000 System Default - 11500 |
|
Timer 4 – Normal proving period ( |
500 - 5000 System Default - 2300 |
|
Timer 4 – Emergency proving period
( |
200 - 1000 System Default - 600 |
|
Timer 5 – Sending
SIB ( |
40 - 500 System Default - 100 |
|
Timer 6 – Remote congestion ( |
1000 - 10000 System Default - 4000 |
|
Timer 7 – Excessive delay of acknowledgment
( |
200 - 3000 System Default - 1500 |
| NODATA - See the Notes. |
100 - 500 System Default - 100 |
|
Notes:
|
|
Table 3-18 Level 2 Timer Values - Low-Speed ITU Signaling Links
| Level 2 Timers | Level 2 Timer Sets 11 - 20 (in milliseconds) |
|---|---|
|
Timer 1 – Aligned ready ( |
40000 - 50000 System Default - 40000 |
|
Timer 2 – Not aligned ( |
5000 - 150000 System Default - 30000 |
|
Timer 3 – Aligned ( |
1000 - 2000 System Default - 2000 |
|
Timer 4 – Normal proving period ( |
7500 - 9500 System Default - 8200 |
|
Timer 4 – Emergency proving period
( |
400 - 600 System Default - 500 |
|
Timer 5 – Sending
SIB ( |
80 - 120 System Default - 100 |
|
Timer 6 – Remote congestion ( |
3000 - 6000 System Default - 4000 |
|
Timer 7 – Excessive delay of acknowledgment
( |
500 - 2000 System Default - 1500 |
| NODATA - See the Notes. |
100 - 500 System Default - 100 |
|
Notes:
|
|
Table 3-19 Level 2 Timer Values - ITU-N High-Speed Signaling Links for China
| Level 2 Timers | Level 2 Timer Sets 21 - 25 (in milliseconds) |
|---|---|
|
Timer 1 – Aligned ready ( |
25000 - 350000 System Default - 150000 |
|
Timer 2 – Not aligned ( |
5000 - 150000 System Default - 130000 |
|
Timer 3 – Aligned ( |
1000 - 2000 System Default - 1000 |
|
Timer 4 – Normal proving period ( |
3000 - 70000 System Default - 30000 |
|
Timer 4 – Emergency proving period
( |
400 - 600 System Default - 500 |
|
Timer 5 – Sending
SIB ( |
80 - 120 System Default - 100 |
|
Timer 6 – Remote congestion ( |
3000 - 6000 System Default - 5000 |
|
Timer 7 – Excessive delay of acknowledgment
( |
500 - 2000 System Default - 800 |
Table 3-20 Level 2 Timer Values - ITU-N High-Speed Signaling Links for Areas other than China
| Level 2 Timers | Level 2 Timer Sets 26 - 30 (in milliseconds) |
|---|---|
|
Timer 1 – Aligned ready ( |
25000 - 350000 System Default - 300000 |
|
Timer 2 – Not aligned ( |
5000 - 150000 System Default - 130000 |
|
Timer 3 – Aligned ( |
1000 - 2000 System Default - 1000 |
|
Timer 4 – Normal proving period ( |
3000 - 70000 System Default - 30000 |
|
Timer 4 – Emergency proving period
( |
400 - 600 System Default - 500 |
|
Timer 5 – Sending
SIB ( |
80 - 120 System Default - 100 |
|
Timer 6 – Remote congestion ( |
3000 - 6000 System Default - 5000 |
|
Timer 7 – Excessive delay of acknowledgment
( |
500 - 2000 System Default - 800 |
Table 3-21 Level 2 Timer Values - Unchannelized T1 High-Speed Signaling Links
| Level 2 Timers | Level 2 Timer Sets 31- 35 (in milliseconds) |
|---|---|
|
Timer 1 – Aligned ready ( |
16000 - 151000 System Default - 151000 |
|
Timer 2 – Not aligned ( |
5000 - 14000 System Default - 14000 |
|
Timer 3 – Aligned ( |
5000 - 14000 System Default - 14000 |
|
Timer 4 – Normal proving period ( |
3000 - 30000 System Default - 30000 |
|
Timer 4 – Emergency proving period
( |
3000 - 10000 System Default - 3000 |
|
Timer 5 – Sending
SIB ( |
80 - 120 System Default - 80 |
|
Timer 6 – Remote congestion ( |
3000 - 6000 System Default - 3000 |
|
Timer 7 – Excessive delay of acknowledgment
( |
500 - 2000 System Default - 500 |
The examples in this procedure are used to change the values of the level 2 timer set number 2.
Figure 3-23 Changing Level 2 Timers