Go to primary content
Oracle® Communications EAGLE Database Administration - SS7 User's Guide
Release 46.7
E97335 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

Unsolicited Messages

There are two types of unsolicited messages that are generated, alarm messages (UAMs) and information messages (UIMs).

Link Unavailability UAMs

The signaling link UAM format includes a CLASS output. This identifies the corresponding link as either an MTP2 or SAAL link class (the SAAL link class is used for high-speed signaling links).

Example:

    0044.0200    SLK 1201,A sp1        RCVRY-LKF: link available
                 SLC=01   FECLLI=A1234567890                CLASS=SAAL

    0044.0200    SLK 1202,A sp2        RCVRY-LKF: link available
                 SLC=01   FECLLI=A1234567890                CLASS=MTP2

Table C-3 provides a summary of high-speed signaling link and low-speed signaling link unavailable reasons listed from highest priority to lowest.

Table C-7 shows the UAMs that correspond link failures on an high-speed signaling link. All signaling link alarms have a severity level of major, except for UAM 200, which shows that the link failure has been cleared. All alarms are output to the Link Maintenance output group.

Table C-7 Signaling Link Unsolicited Alarm Messages

Link Failure UAM Number UAM Text

Recovery: Link Available

0200

RCVRY-LKF: link available

Failure: Remote NE Loopback

0201

REPT-LKF: remote NE loopback

Failure: Hardware Problems

0202

REPT-LKF: HWP - too many link interrupts

Failure: Failed Remote FE Loopback

0202

REPT-LKF: remote FE loopback

Failure: MTP3 Changeover Order (COO) Message Received

0218

REPT-LKF: COO - rcvd changeover order

Management Inhibit: Remote

0234

REPT-LKF: RMI remote inhibited

Management Inhibit: Local

0235

REPT-LINK-MGTINH: local inhibited

Failure: Unresolved - Default failure reason

0236

REPT-LKF: not aligned

Failure: False Congestion Restart

0236

REPT-LKF: false congestion restart

Failure: MTP Link Restart Delayed

0236

REPT-LKF: MTP link restart delayed

Excessive Duration of Far End Receiving Congestion

0237

REPT-LKF: LM Timer NO-CREDIT expired

Excessive Delay of Acknowledgment

0238

REPT-LKF: XDA - Timer NO-RESPONSE expired

Local Processor Outage(management initiated)

0239

REPT-LKF: MBL - local processor outage

SSCF Remote Release: Remote Processor Outage

0240

REPT-LKF: rcvd SSCOP END-proc. outage

SSCF Remote Release: Out of Service

0241

REPT-LKF: rcvd SSCOP END-out of service

SSCF Remote Release: Protocol Error

0242

REPT-LKF: rcvd SSCOP END-protocol error

SSCF Remote Release: Management Initiated

0243

REPT-LKF: rcvd SSCOP END-mgmnt initiated

Facility Outage - DS1 Loss of Signal failure

0244

REPT-LKF: FAC - DS1 LOS failure

Facility Outage - DS1 Loss of Frame failure

0245

REPT-LKF: FAC - DS1 LOF failure

Facility Outage - DS1 Loss of Cell Delineation failure

0246

REPT-LKF: FAC - DS1 LCD failure

Excessive In Service Error Rate

0247

REPT-LKF: XER - ISERM threshold exceeded

UIMs

There are two types UIMs generated with ATM high-speed signaling links, UIMs for large MSUs and UIMs for the loopback tests. UIMs 1172 and 1173 are generated for MTP MSUs (1172) and SCCP MSUs (1173).

The large MSUs are discarded at the receiving ATM high-speed signaling link rather than the outbound link.

UIM 1172 Example

0018.1172    CARD 1103    INFO  REPT-OVSZMSG: MTP MSU too large to route.
             LEN=279  SIO=03  DPC=001-001-001  OPC=002-002-002
             LSN=A1234567
    Report Date: 97-10-30  Time: 16:27:19

UIM 1173 Example

0018.1173    CARD 1103    INFO  REPT-OVSZMSG: SCCP MSU too large to route.
             LEN=279  SIO=03  DPC=001-001-001  OPC=002-002-002  MSG TYPE=09
             CDPA:  AI=8B  PC=003-003-003  SSN=005  TT=250  ADDR=1234567890
             CGPA:  AI=8B  PC=004-004-004  SSN=006  TT=251  ADDR=0123456789
             LSN=A1234567
    Report Date: 97-10-30  Time: 16:27:19

The UIMs shown in Table C-8 are generated when loopback tests performed on the ATM high-speed signaling link are completed.

Table C-8 Loopback Test UIMs

UIM # Severity Message Text UIM is Generated When …

1156

None

Loopback success

loopback test passes.

1157

None

Loopback failed

loopback test failed.

1158

None

Loopback aborted

request to activate link is received while running a loopback.

1159

None

Loopback in progress

loopback request received while the same loopback test is already in progress.

1170

None

Loopback prevented

loopback setup was not performed because the specified type of loopback requires a BOC to be transmitted and this function was prevented from transmitting a BOC.

1171

None

Loopback invalid

loopback setup was not performed because invalid parameters were provided.