| Oracle® Communications EAGLE Database Administration - SS7 User's Guide Release 46.7 E97335 Revision 1 |
|
![]() Previous |
![]() Next |
This procedure is used to increase the number of proxy point codes that are allowed in the EAGLE. The EAGLE can contain a maximum of 100 proxy point codes.
The enable-ctrl-feat command enables the proxy point code quantity, in groups of 10 proxy point codes, by specifying the part number for the proxy point code quantity and the proxy point code quantity’s feature access key with these parameters:
Note:
As of Release 46.3, thefak parameter is no longer required. This parameter is only used for backward compatibility.:fak – The feature access key supplied by Oracle. The feature access key contains 13 alphanumeric characters and is not case sensitive. If you do not have the feature access key for the proxy point code quantity you wish to enable, contact your Oracle Sales Representative or Account Representative.
:partnum – The Oracle-issued part number for the proxy point code quantity shown in the following table:
Table 2-4 Proxy Point Code Quantities and Part Numbers
| Part Number | Proxy Point Code Quantity |
|---|---|
| 893018701 | 10 |
| 893018702 | 20 |
| 893018703 | 30 |
| 893018704 | 40 |
| 893018705 | 50 |
| 893018706 | 60 |
| 893018707 | 70 |
| 893018708 | 80 |
| 893018709 | 90 |
| 893018710 | 100 |
The enable-ctrl-feat command requires a valid serial number for the EAGLE to be configured in the database, and that this serial number is locked. This can be verified with the rtrv-serial-num command. The EAGLE is shipped with a serial number in the database, but the serial number is not locked. The serial number can be changed, if necessary, and locked once the EAGLE is on-site, by using the ent-serial-num command. The ent-serial-num command uses these parameters.
:serial – The serial number assigned to the EAGLE. The serial number is not case sensitive.
:lock – Specifies whether or not the serial number is locked. This parameter has only one value, yes, which locks the serial number. Once the serial number is locked, it cannot be changed.
Note:
To enter and lock the EAGLE’s serial number, theent-serial-num command must be entered twice, once to add the correct serial number to the database with the serial parameter, then again with the serial and the lock=yes parameters to lock the serial number. You should verify that the serial number in the database is correct before locking the serial number. The serial number can be found on a label affixed to the control shelf (shelf 1100).Once the proxy point code quantity is enabled with the enable-ctrl-feat command, the proxy point code is also turned on. The chg-ctrl-feat command is not necessary to turn on the proxy point code quantity.
Figure 2-7 Changing the Proxy Point Code Quantity
Sheet 1 of 3
Sheet 2 of 3
Sheet 3 of 3