0350 - OAP Terminals Inhibited

This message indicates that the OAP terminals are inhibited.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0
*C 0100.0350  *C  SEAS SYSTEM     OAP terminals inhibited

Alarm Level: Critical

Recovery

  1. Enter the following command to determine which ports are inhibited:
    rept-stat-seas

    Following is an example of the output:

    RLGHNCXA03W 00-04-17 14:59:11 EST  EAGLE 35.0.0
                             GPL        PST         SST           AST
    ---------------------------------------------------------------------
    SEAS SYSTEM                         IS-ANR      Restricted    -----
    TDM TRM           6                 IS-NR       Active        -----
    TDM TRM           9                 IS-NR       Active        -----
    OAP              A    220-001-000   IS-NR       Active        -----
    OAP              B    -----------   OOS-MT      Isolated      -----
    X25 Link         A1                 IS-NR       Active        -----
    X25 Link         B1                 OS-MT       Fault         -----
    SEAS SYSTEM  ALARM STATUS = *C 0350  OAP terminals inhibited
    OAP A        ALARM STATUS = No Alarms.
    OAP B        ALARM STATUS = ** 0341 OAP unavailable
    X25          ALARM STATUS = No Alarms.
    X25          ALARM STATUS = ** 0358 LSMS Q.3 association unavailable
    X25 A1 PVCs IS-NR   = 1,2,3
    X25 A1 PVCs OOS-MT  = ---
    X25 B1 PVCs IS-NR   = ---
    X25 B1 PVCs OOS-MT  = 1,2,3
    Command Completed.

    Refer to the Commands Manual to interpret the output.

  2. Enter the following command to verify that the other serial port devices are functioning:
    rept-stat-trm

    Following is an example of the output:

    RLGHNCXA03W 00-02-07 09:50:17 EST  EAGLE 35.0.0
        TRM  PST           SST           AST
        1     IS-NR         Active        -----
        2     IS-NR         Active        -----
        3     IS-NR         Active        ALMINH
        4     IS-NR         Active        -----
        5     OOS-MT-DSBLD  Manual        -----
        6     IS-NR         Active        -----
        7     IS-NR         Active        -----
        8     IS-NR         Active        -----
        9     IS-NR         Active        -----
        10    IS-NR         Active        -----
        11    IS-NR         Active        ALMINH
        12    IS-NR         Active        -----
        13    IS-NR         Active        -----
        14    IS-NR         Active        -----
        15    IS-NR         Active        -----
        16    IS-NR         Active        -----
        Command Completed.

    Refer to the Commands Manual to interpret the output.

  3. If only the SEAS port(s) are not functioning, enable the SEAS port(s) with the following command:
    rst-trm:trm=x

    where x is the OAP port number. If this action corrects the problem, you are done with this procedure.

  4. Enter the following command to inhibit the unavailable OAP terminal displayed in the output from 1:
    inh-trm:trm=x
    where x is the port number.

    Note:

    The force parameter is required for the last OAP terminal inhibited.
  5. Enter the following command for the inhibited OAP terminal:
    chg-trm:trm=x:type=none

    where x is the port number.

  6. If the problem is still not corrected, reseat the TDM card.
    If the problem persists, replace the TDM card. Refer to the Maintenance Manual for card removal/replacement procedures.
  7. Enter the following command for each OAP terminal inhibited:
    chg-trm:trm=x:type=oap

    where x is the port number.

  8. Enter the following command to return the OAP terminals to the in-service state:
    alw-trm:trm=x

    where x is the port number.