0619 - SIP SYSTEM is Not Available

This alarm indicates SIP feature is not ON and System has no SIP card that is Active/IS-NR.

Example
1         2         3         4         5         6         7         8
12345678901234567890123456789012345678901234567890123456789012345678901234567890   
*C  0002.0619 *C SIP SYSTEM             SIP System is not available

Alarm Level: Critical

Recovery

  1. Enter the following command to verify the status and location of the SIP card: rept-stat-sip.
  2. Enter the following command to move the SIP card to an ACTIVE status if loading is successful: rst-card:loc=xxx where xxxx is the location of the SIP card identified in 1.
  3. Enter the following command to verify the status and location of the SIP card: rept-stat-sip.
  4. Verify the SIP card reset in 2 are ACTIVE/IS-NR.
  5. If the SIP card remains INACTIVE, replace the card. Refer to the Maintenance Manual for card removal/replacement procedures.