0619 - SIP SYSTEM is Not Available
This alarm indicates SIP feature is not ON and System has no SIP card that is Active/IS-NR.
Example
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678901234567890
*C 0002.0619 *C SIP SYSTEM SIP System is not available
Alarm Level: Critical
Recovery
- Enter the following command to verify the status and
location of the SIP card:
rept-stat-sip
. - Enter the following command to move the SIP card to
an ACTIVE status if loading is successful:
rst-card:loc=xxx
where xxxx is the location of the SIP card identified in 1. - Enter the following command to verify the status and
location of the SIP card:
rept-stat-sip
. - Verify the SIP card reset in 2 are ACTIVE/IS-NR.
- If the SIP card remains INACTIVE, replace the card. Refer to the Maintenance Manual for card removal/replacement procedures.