1010 - GWS rcvd a priority that is not allowed

This message indicates gateway screening (GWS) has discarded an MSU because the priority is listed as one that is not allowed in this network.

Example
RLGHNCXA21W 00-02-07 11:02:30 EST  EAGLE 35.0.0
0100.1010    CARD 1205,A  INFO   GWS rcvd a priority that is not allowed
SIO=0a   OPC=003-242-000  DPC=000-071-000
H0H1=54  AFTPC=03-03-03
SR=osp3   LSN=A1234567

Note:

Four outputs are possible. The Legend includes abbreviations found in all variations.

Legend
ADDR
Address
AFTPC
Affected point code (for SCCP messages)
AFTSS
Affected subsystem (identifies the subsystem that failed)
AI
Address Indicator
CDPA
Called party address
CGPA
Calling party address
DATA
Information from the upper layers of SCCP management
DPC
Destination point code
H0H11
H0/H1 heading code
LSN
Linkset name. The name must be unique.
MULT
SCCP management message multiplicity indicator
OPC
Origination point code
PC
Point code for the SS7 end user (OPC).
SCCP MT
SCCP message type
SCMG
SCCP management message
SIO
Service information octet
SR
Screening reference name
SSN
Subsystem number
TT
Translation type
TYPE
SCCP management message type

Alarm Level: No alarm condition. The message is informational only.

Recovery

  1. This indicates that a MSU was discarded because it failed screening.
    No action is necessary, unless the MSU should have passed. If the MSU should have passed (verified by the fields displayed in the above message), go to 2.
  2. Using the rtrv-scr-sio command, verify that the screening reference specified in the above message does not allow MSUs with the priority value indicated.
  3. If the MSU should have passed screening, use the chg-scr-sio command to add the pri data to the screening reference.