1093 - ITU GWY:rcvd msg type cannot convert
This message indicates the STP received a message type that has no equivalent in the opposite protocol. Table 3-10 shows the list of message types that have no equivalents and are discarded.
Table 3-10 Message Type with No Opposite Protocol Equivalent
Message Type | Code |
---|---|
Confusion Message (CNF) | 2F |
Connect Message (CONN) | 07 |
Continuity Test Message (COT) | 05 |
Continuity Check Request Message (CCR) | 11 |
Information Message (INF) | 04 |
Information Request Message (INR) | 03 |
Loop Back Acknowledge Message (LPA) | 24 |
Overload Message (OLM) | 30 |
Example
station5 00-04-18 19:12:00 EST EAGLE 31.3.0
0110.1093 CARD 1205,B INFO ITU GWY:rcvd msg type cannot convert
SIO=0e OPC=4-013-1 DPC=1-003-0
MSG TYPE=07
LSN=A1234567890
Legend
Alarm Level: No alarm condition. The message is informational only.
Recovery
Check translations on the originating switch to determine the trouble.