Oracle® Communications EAGLE Unsolicited Alarm and Information Messages Reference Release 46.7 E97338_01 |
|
![]() Previous |
![]() Next |
This message indicates that the OAP terminal specified in the output message is not available.
RLGHNCXA21W 00-02-07 11:02:30 EST EAGLE 35.0.0 ** 0100.0354 ** OAP B One OAP terminal unavailable
Alarm Level: Major
Recovery
rept-stat-seas
Following is an example of the output:
RLGHNCXA03W 00-04-17 14:59:11 EST EAGLE 35.0.0 GPL PST SST AST --------------------------------------------------------------------- SEAS SYSTEM IS-ANR Restricted ----- TDM TRM 6 IS-NR Active ----- TDM TRM 9 IS-NR Active ----- OAP A 220-001-000 IS-NR Active ----- OAP B ----------- OOS-MT Isolated ----- X25 Link A1 IS-NR Active ----- X25 Link B1 OS-MT Fault ----- SEAS SYSTEM ALARM STATUS = ** 0362 LSMS is at min service limit OAP A ALARM STATUS = No Alarms. OAP B ALARM STATUS = ** 0354 One OAP terminal unavailable X25 ALARM STATUS = No Alarms. X25 ALARM STATUS = ** 0358 LSMS Q.3 association unavailable X25 A1 PVCs IS-NR = 1,2,3 X25 A1 PVCs OOS-MT = --- X25 B1 PVCs IS-NR = --- X25 B1 PVCs OOS-MT = 1,2,3 Command Completed.
Refer to the Commands Manual to interpret the output.
rept-stat-trm
Following is an example of the output:
RLGHNCXA03W 00-02-07 09:50:17 EST EAGLE 35.0.0 TRM PST SST AST 1 IS-NR Active ----- 2 IS-NR Active ----- 3 IS-NR Active ----- 4 OOS-MT-DSBLD MANUAL ----- 5 IS-NR Active ----- 6 IS-NR Active ----- 7 IS-NR Active ----- 8 IS-NR Active ----- 9 IS-NR Active ----- 10 IS-NR Active ----- 11 IS-NR Active ----- 12 IS-NR Active ----- 13 OOS-MT-DSBLD MANUAL ----- 14 OOS-MT-DSBLD MANUAL ----- 15 OOS-MT-DSBLD MANUAL ----- 16 OOS-MT-DSBLD MANUAL ----- Command Completed.
Refer to the Commands Manual to interpret the output.
rst-trm:trm=x
where x is the serial port number. If this action corrects the problem, you are done with this procedure.
inh-trm:trm=x
Note:
The force parameter is required for the last OAP terminal inhibited. init-oap:oap=x
where x is the OAP to be initialized. Verify that the OAP comes back in-service within five minutes and the system clears the alarm. If this clears the alarm, continue with 10.
chg-trm:trm=x:type=none
where x is the port number.
chg-trm:trm=x:type=oap
where x is the port number.
alw-trm:trm=x