This message occurs when there is an ANSI message with no ITU equivalent. Table 3-9 shows the ANSI messages with no ITU equivalent.
Table 3-9 ANSI Messages with No ITU Equivalent
Message | H0/H1 Code (Hex) |
---|---|
Transfer Restricted (TFR) when generated by an ITU National network | 43 |
Transfer-Cluster Restricted (TCR) | 44 |
Transfer-Cluster Allowed (TCA) | 46 |
Transfer-Cluster Prohibit Signal (TCP) | 42 |
station5 00-04-18 19:12:00 EST EAGLE 31.3.0 0010.1092 CARD 1205,B INFO ITU GWY: H0H1 conversion failure SIO=08 OPC=003-235-001 DPC=006-006-000 H0H1=42 LSN=A1234567890
Alarm Level: No alarm condition. The message is informational only.
Recovery
Check translations on the originating switch to determine the trouble.