E3877 Cmd Rej: ANSI/ITU point code type mismatch

For the ent/chg-rte command, all linksets in a routeset must have the same network type. The network type of the routeset must be the same as the network type of the destination point code.

For the ent/chg-rtx command, the network domain of the adjacent point code (APC) in the linkset or of the routes in the specified routeset must be the same network domain of the specified destination point code or its alias.

For the chg-dstn command, the network type of the routeset must be the same as the network type of the destination point code.

Recovery

  1. Display the linksets in the database. Enter the rtrv-ls command.
    The APCs of the linksets are shown in the APCA, APCI, and APCN fields of the output.
  2. Display the DPCs in the database. Enter the rtrv-dstn command.
    The DPCs are shown in the DPCA, DPCI, and DPCN fields of the output.
  3. Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide and to the Database Administration - SS7 User's Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).