E3570 Cmd Rej: Point Code type does not match GTT Set network domain
The ANSI/ITU SCCP Conversion feature must be enabled before a translated point code that is of a different domain than the GTT set specified by the gttsn parameter can be specified.
Recovery
Display the status of the ANSI/ITU SCCP Conversion feature. Enter the rtrv-ctrl-feat command.
If the feature does not appear in the output, then the feature is not enabled. If the feature has a status of OFF, then the feature is enabled but is not turned on.
Display the network domain of the GTT set. Enter the rtrv-gttset command.
The network domain is listed in the NETDOM column of the output.
Enable the ANSI/ITU SCCP Conversion feature as necessary. Refer to the Database Administration - GTT User's Guide for assistance.
Re-enter the ent/chg/dlt/rtrv-gta command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide and to the Database Administration - GTT User's Guide for assistance.