E3514 Cmd Rej: Maximum of 10 unique CCNCs allowed

A maxiumum of 10 sets of ccnc/mccmnc parameter combinations are allowed.

Recovery

  1. Display the existing ccnc/mccmnc combinations. Enter the rtrv-gsmopts command.
  2. Delete an existing ccnc/mccmnc parameter combination as necessary. Refer to the G-Port User's Guide for assistance.
  3. Re-enter the chg-gsmopts command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).