Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E4077 Cmd Rej: Parameters incompatible with adapter type

If an IPSG-M3UA signaling link is used, then the alw/inh/tst/unhb-slk commands cannot be entered.

For the tst-slk command, if an IPSG-M2PA signaling link is used, then the loopback=sltc parameter must be specified.

For the ent-assoc command, if the card is running the IPLIM or IPLIMI application, then the lhost parameter can only have an association with an adapter value of m2pa.

Recovery

  1. Display the type of signaling link used. Enter the rtrv-slk command.
  2. Display the application on the card. Enter the rtrv-card command.
  3. Display the type of association used. Enter the rtrv-assoc command.
  4. Re-enter the command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide and to the Database Administration - IP7 User's Guide for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).