ANSI point code value 000-000-000 and ITU-International point code value 0-000-0 are not allowed.
The ITU-National point code must be a full point code. A full point code is specified with a numerical value for the nnnnn segment of the point code.
If the ITUDUPPC (ITU national duplicate point code) feature is on, then the ITU national point code will also contain a group code. The group code is a two-character field from aa to zz that is entered as the last subfield of an ITU-N point code, nnnnn-gc (for example, 2112-aa).
Note:
Once a feature this is controlled using a feature bit has been turned on, it cannot be turned off.A flexible point code format can be assigned with the chg-stpopts:npcfmti parameter. Refer to the command description for the chg-stpopts command in Commands User's Guide for assistance.
An asterisk (*) cannot be used to enter or change ITU national point codes. The asterisk is allowed only for retrieving ITU national point codes.
Recovery