Go to primary content
Oracle® Communications EAGLE Commands Error Recovery Reference
Release 46.8
F11879 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

E2587 Cmd Rej: Card GPL of link does not match domain of linkset APC

The domain of the linkset specified by the lsn parameter must match the domain of the link specified by the link parameter.

Recovery

  1. Display the card applications of the cards in the system. Enter the rtrv-card command.
  2. Display the APC for the linkset. Enter the rtrv-ls command.
    The application assigned to the card determines the domain of the signaling link.
  3. Display the destination point codes and verify the domain (SS7) of each destination point code. Enter the rtrv-dstn command.
  4. Re-enter the ent-slk command that generated this error message, specifying a valid combination of parameters. Refer to the command description in Commands User's Guide, the Database Administration - SS7 User's Guide (SS7 signaling link) and to the Database Administration - IP7 User's Guide (IP signaling link) for assistance.
    Contact My Oracle Support if this error message appears again. See My Oracle Support (MOS).