Adding an IPLIMx Card

This procedure is used to add an IPLIMx card to the database using the ent-card command. An IPLIMx card runs either the IPLIM or IPLIMI applications. A maximum of 100 IPLIMx cards can be provisioned in the database. Table 3-1 shows the cards that can be provisioned in this procedure.

Table 3-1 IPLIMx Card Types

Card Type Part Number
E5-ENET 870-2212-xx
E5-ENET-B 870-2971-xx

The EAGLE can support a combination of E5-ENET and E5-ENET-B cards.

The ent-card command uses these parameters.

:loc – The location of the card being added to the database.

:type – The type of card being added to the database. For this procedure, the value of this parameter is dcm.

:appl – The application software that is assigned to the card. For this procedure, the value of this parameter is iplim for ANSI IP network connections or iplimi for ITU IP network connections.

:force – If the global title translation feature is on, the force=yes parameter allows the LIM to be added to the database even if the current SCCP transactions-per-second threshold is unable to support the additional SCCP transaction-per-second capacity created by adding the IP card. This parameter is obsolete and is no longer used.

Card Slot Selection

The E5-ENET card can be inserted into any card slot, except for card slots that must remain empty to accommodate dual-slot cards, slots 09 and 10 in each shelf, and slots 1113 through 1118.

To provision a E5-ENET card, the shelf containing the E5-ENET card must have HIPR2 cards installed in slots 9 and 10 in that shelf. If HIPR2 cards are not installed in the shelf that the E5-ENET card will occupy, the E5-ENET card will be auto-inhibited when the E5-ENET card is inserted into the shelf. Enter the rept-stat-gpl:gpl=hipr2 command to verify whether or not HIPR2 cards are installed in the same shelf as the E5-ENET card being provisioned in this procedure.

Before adding an IPLIMx card, the Eagle STP must have a fan unit, and the fan feature must be turned on. Also, the MFC STP option must be on.

  1. Display the cards in the database using the rtrv-card command.

    This is an example of the possible output. Cards should be distributed throughout the EAGLE for proper power distribution. Refer to Installation Guide for the shelf power distribution.

    rlghncxa03w 09-05-05 08:12:53 GMT  41.0.0
    CARD   TYPE      APPL      LSET NAME     LINK SLC LSET NAME     LINK SLC
    1101   DSM       VSCCP     
    1102   TSM       GLS       
    1113   GSPM      EOAM
    1114   TDM-A
    1115   GSPM      EOAM
    1116   TDM-B
    1117   MDAL
    1201   LIMDS0    SS7ANSI   sp2           A    0   sp1           B    0
    1203   LIMDS0    SS7ANSI   sp3           A    0   
    1204   LIMDS0    SS7ANSI   sp3           A    1   
    1206   LIMDS0    SS7ANSI   nsp3          A    1   nsp4          B    1
    1216   DCM       STPLAN    
    1301   LIMDS0    SS7ANSI   sp6           A    1   sp7           B    0
    1302   LIMDS0    SS7ANSI   sp7           A    1   sp5           B    1
    1303   DCM       IPLIM     ipnode1       A    0   ipnode3       B    1
    1305   DCM       IPLIM     ipnode4       A    0   
    1307   DCM       STPLAN
    2101   ENET      IPSG
    2103   ENET      IPSG
    2105   ENET      IPSG
    2107   ENET      IPSG
    2201   DCM       IPLIM
    2203   DCM       IPLIM
    2207   DCM       IPLIM
    2211   DCM       SS7IPGW
    2213   DCM       SS7IPGW
    2215   DCM       IPGWI
    2217   DCM       IPGWI
    2301   DCM       SS7IPGW
    2303   DCM       SS7IPGW
    2305   DCM       IPGWI
    2307   DCM       IPGWI
    2311   DCM       IPLIMI
    2313   DCM       IPLIMI
    Continue the procedure by performing one of these steps.
    • If the required unprovisioned card slots (see the section Card Slot Selection) are shown in the rtrv-card output, continue the procedure with 4.
    • If the required unprovisioned card slots are not shown in the rtrv-card output, 2 must be performed.
  2. Display the shelves in the database by entering the rtrv-shlf command. This is an example of the possible output.
    rlghncxa03w 08-03-05 08:12:53 GMT  38.0.0
    SHELF DISPLAY
    FRAME SHELF        TYPE
      1     1       CONTROL
      1     2       EXTENSION
      1     3       EXTENSION
      2     1       EXTENSION
      2     2       EXTENSION
      2     3       EXTENSION

    If all the shelves are provisioned in the database, then the remainder of this procedure cannot be performed. There are no available card slots for the new IPLIMx card.

    If all the shelves have not been provisioned in the database, continue the procedure with 3.

  3. Add the required shelf using the ent-shlf command with the location of the shelf and the type=ext parameter. The shelf location values are 1200, 1300, 2100, 2200, 2300, 3100, 3200, 3300, 4100, 4200, 4300, 5100, 5200, 5300, and 6100. For this example, enter this command.

    ent-shlf:loc=3100:type=ext

    When this command has successfully completed, this message should appear.

    rlghncxa03w 07-05-01 09:12:36 GMT  EAGLE5 37.0.0
    ENT-SHLF: MASP A - COMPLTD
  4. Verify that the card to be entered has been physically installed into the proper location (see the section Card Slot Selection).

    Caution:

    If the versions of the flash GPLs on the IPSG card do not match the flash GPL versions in the database when the IPSG card is inserted into the card slot, UAM 0002 is generated indicating that these GPL versions do not match. If UAM 0002 has been generated, perform the alarm clearing procedure for UAM 0002 in Maintenance Guide before proceeding with this procedure.

    Note:

    If the card being added in this procedure is not an E5-ENET card, continue the procedure with 10.
  5. Verify that HIPR2 cards are installed in card locations 9 and 10 in the shelf containing the E5-ENET card being added in this procedure. Enter this command.

    rept-stat-gpl:gpl=hipr2

    This is an example of the possible output.

    
    rlghncxa03w 09-07-05 08:12:53 GMT  41.1.0
    GPL        CARD      RUNNING            APPROVED      TRIAL
    HIPR2      1109      132-002-000        132-002-000   132-003-000
    HIPR2      1110      132-002-000        132-002-000   132-003-000
    HIPR2      1209      132-002-000        132-002-000   132-003-000
    HIPR2      1210      132-002-000        132-002-000   132-003-000
    HIPR2      1309      132-002-000        132-002-000   132-003-000
    HIPR2      1310      132-002-000        132-002-000   132-003-000
    HIPR2      2109      132-002-000        132-002-000   132-003-000
    HIPR2      2110      132-002-000        132-002-000   132-003-000
    HIPR2      2209      132-002-000        132-002-000   132-003-000
    HIPR2      2210      132-002-000        132-002-000   132-003-000
    HIPR2      2309      132-002-000        132-002-000   132-003-000
    HIPR2      2310      132-002-000        132-002-000   132-003-000
    Command Completed
    

    If HIPR2 cards are installed in the shelf containing the E5-ENET card, continue the procedure with 10.

    If HIPR or HIPR2 cards are not installed on the shelf containing the E5-ENET card, go to Installation Guide and install the HIPR2 cards. Once the HIPR2 cards have been installed, continue the procedure with 10.

  6. Enter the rtrv-stpopts command to verify whether or not the MFC option is on.

    This is an example of the possible output.

    
    
    rlghncxa03w 11-10-17 16:02:05 GMT EAGLE5 44.0.0
    STP OPTIONS         
    ---------------------------
    MFC                     off
    
    

    The rtrv-stpopts command output contains other fields that are not used by this procedure. To see all fields displayed by the rtrv-stpopts command, see the rtrv-stpopts command description in Commands User's Guide.

    If the MFC option is off, perform the Configuring the MFC Option procedure in Database Administration - System Management User's Guide to turn on the MFC option.

    If the MFC option is on or the MFC Option procedure in Database Administration - System Management User's Guide was performed in this step, continue the procedure with 7.

    The Fan feature must be purchased before you turn this feature on with the chg-feat command. If you are not sure if you have purchased the Fan feature, contact your Sales Representative or Account Representative.

  7. Enter the rtrv-feat command to verify that the Fan feature is on.

    If the Fan feature is on, shown in either the rtrv-feat output in this step or in 7, continue this procedure with 9.

    If 7 was not performed, the FAN field should be set to on.

    The rtrv-feat command output contains other fields that are not used by this procedure. To see all fields displayed by the rtrv-feat command, see the rtrv-feat command description in Commands User's Guide.

    If the Fan feature is off, continue the procedure with 8.

  8. Turn the Fan feature on by entering this command.

    chg-feat:fan=on

    Note:

    Once the Fan feature is turned on with thechg-feat command, it cannot be turned off.

    When the chg-feat has successfully completed, this message appears.

    
    rlghncxa03w 11-10-28 11:43:04 GMT EAGLE5 44.0.0
    CHG-FEAT: MASP A - COMPLTD
    
  9. The shelf containing the E5-ENET-B card that is being added in this procedure must have fans installed. Verify whether or not fans are installed on the shelf.

    If the fans are installed, continue the procedure with 10.

    If the fans are not installed on the shelf containing the E5-ENET-B card, go to Installation Guide and install the fans. After the fans have been installed and tested, continue the procedure with 10.

  10. Add the card using the ent-card command. For this example, enter these commands.

    ent-card:loc=1311:type=dcm:appl=iplim

    ent-card:loc=1313:type=dcm:appl=iplimi

    When each of these commands have successfully completed, this message should appear.

    
    rlghncxa03w 06-10-12 09:12:36 GMT EAGLE5 36.0.0
    ENT-CARD: MASP A - COMPLTD
    
  11. Verify the changes using the rtrv-card command with the card location specified in 10. For this example, enter these commands.

    rtrv-card:loc=1311

    This is an example of the possible output.

    
    rlghncxa03w 06-10-28 09:12:36 GMT EAGLE5 36.0.0
    CARD   TYPE      APPL      LSET NAME     LINK SLC LSET NAME     LINK SLC
    1311   DCM       IPLIM
    

    rtrv-card:loc=1313

    This is an example of the possible output.

    
    rlghncxa03w 06-10-28 09:12:36 GMT EAGLE5 36.0.0
    CARD   TYPE      APPL      LSET NAME     LINK SLC LSET NAME     LINK SLC
    1313   DCM       IPLIMI
    
  12. Back up the new changes using the chg-db:action=backup:dest=fixed command. These messages should appear, the active Maintenance and Administration Subsystem Processor (MASP) appears first.
    
    BACKUP (FIXED) : MASP A - Backup starts on active MASP.
    BACKUP (FIXED) : MASP A - Backup on active MASP to fixed disk complete.
    BACKUP (FIXED) : MASP A - Backup starts on standby MASP.
    BACKUP (FIXED) : MASP A - Backup on standby MASP to fixed disk complete.
    

Figure 3-1 Adding an IPLIMx Card



Sheet 1 of 3



Sheet 2 of 3



Sheet 3 of 3