Go to primary content
Oracle® Communications EAGLE Database Administration - SS7 User's Guide
Release 46.8
F11884 Revision 1
Go To Table Of Contents
Contents

Previous
Previous
Next
Next

Adding Channelized and non-Channel Bridged T1 Ports

The channelized and non-channel bridged T1 ports are provisioned in the database using the ent-t1 command using these parameters.

:loc – The location of the T1 card (card type limt1) that is servicing the T1 signaling link. The location of a channel card (card type limch) cannot be specified for this parameter.

:t1port – The T1 port on the T1 card used to service the T1 signaling link. The t1port value cannot already be assigned to the T1 card specified by the loc parameter.

:encode – Specifies the type of encoding or decoding that is used on the T1 signaling link, either B8ZS or AMI. The default value is B8ZS encoding (encode=b8zs).

:t1tsel – The timing source for the T1 signaling link, master (external), slave (line), or recovered. The default value is slave timing (t1tsel=line).

The recovered timing source can be used only with the chanbrdg=on parameter and cannot be used in this procedure.

Note:

To use an external high-speed master clock source other than RS-422, TDMs 870-0774-15 or later must be installed in card locations 1114 and 1116, and the TDM Global Timing Interface options must be configured. For more information, refer to Configuring the Options for the TDM Global Timing Interface.

:framing – Specifies the framing format to be used on the TI signaling link, either sf or esf. The default value is sf (framing=sf).

:ll – The length of the cable, in feet, used for the T1 signaling link. The value of the ll parameter is from 0 to 655. The default value for this parameter is 133.

The ent-t1 command contains other parameters that are not used in this procedure. These parameters and their usage are described in these sections:

The T1 card specified in this procedure must be in the database. This can be verified with the rtrv-card command.

The T1 card cannot contain channelized and unchannelized T1 ports.

  1. Display the existing T1 interfaces in the database using the rtrv-t1 command with no parameters.
    rlghncxa03w 09-05-19 21:17:04 GMT EAGLE5 41.0.0
    
          T1                                              LINK    MINSU
    LOC   PORT  ENCODE  T1TSEL    FRAMING  LL   CHANBRDG  CLASS   RATE
    1207  1     AMI3    EXTERNAL  ESF      50   -----     CHAN    ----
    
    

    Continue the procedure by performing one of these substeps.

    1. If the T1 card that the T1 port is being assigned to in this procedure is not shown in the rtrv-t1 output, or if the T1 card has unchannelized T1 ports assigned to it, continue the procedure with 2 to verify if there are any T1 cards in the database that have no T1 ports assigned to them.
    2. If the rtrv-t1 output shows that the T1 card has channel bridged T1 ports assigned to it, or that T1 ports 3, 4, 5, 6, 7, or 8 are assigned to the T1 card, the T1 card is an HC-MIM or an E5-E1T1 card. Continue the procedure with 7 to add the T1 port with the parameters allowed for an HC-MIM or an E5-E1T1 card.
    3. If the rtrv-t1 output shows that the T1 card does not have channel bridged T1 ports assigned to it, or that T1 ports 3, 4, 5, 6, 7, or 8 are not assigned to the T1 card, verify the type of T1 card that the T1 port will be assigned to. The T1 card types and their part numbers are shown in Table B-4. If the T1 card is an HC-MIM or an E5-E1T1 card, continue the procedure by performing one of these steps.
      • If the T1 cards shown in this step are on the same shelf as the card that will contain the T1 port that is being added, and these cards have T1 ports 3 through 8 provisioned, contain channel bridged T1 ports, or unchannelized T1 ports, continue the procedure with 7.
      • If the T1 cards shown in this step are not on the same shelf as the card that will contain the T1 port that is being added, continue the procedure with 3.
      • If the T1 cards shown in this step are on the same shelf as the card that will contain the T1 port that is being added, and these cards do not have T1 ports 3 through 8 provisioned, do not contain channel bridged T1 ports, or do not have unchannelized T1 ports, continue the procedure with 3.
    4. If the T1 card you wish to use in this procedure has all the T1 ports that are allowed to be assigned to it, select another T1 card to add the T1 port to, or continue the procedure with 2 to verify if there are any T1 cards in the database that have no T1 ports assigned to them. Table B-7 shows the number of T1 ports that are allowed for the different T1 card types.

      Table B-7 Maximum Number of T1 Ports

      T1 Card Types Maximum Number of T1 Ports

      HC-MIM

      8

      E5-E1T1

      8

  2. Display the cards in the EAGLE using the rtrv-card command.
    rlghncxa03w 09-05-28 09:12:36 GMT EAGLE5 41.0.0
    CARD   TYPE      APPL     LSET NAME   LINK SLC LSET NAME   LINK SLC
    1102   TSM       GLS      
    1113   GSPM      OAM
    1114   TDM-A
    1115   GSPM      OAM
    1116   TDM-B
    1117   MDAL
    1207   LIMT1     SS7ANSI  lsnt265     A    0  
    1208   LIMCH     SS7ANSI  lsnt265     A    1  lsnt265      A2   2  
    1211   LIME1     CCS7ITU  lsne145     A    0  
    1212   LIMCH     CCS7ITU  lsne145     A    1  lsne145      A2   2  
    1215   LIMT1     SS7ANSI  
    1216   LIMCH     SS7ANSI  
    1316   DCM       STPLAN   
    

    Continue the procedure by performing one of these substeps.

    1. If the desired T1 card is not shown in the rtrv-card output, perform Adding a LIM-T1 Card to add the desired T1 card. If you wish to assign T1 ports 3, 4, 5, 6, 7, or 8 to the T1 card, the T1 card being added must be an HC-MIM or an E5-T1T1 card.
    2. If the desired T1 card is shown in the rtrv-card output, verify the type of T1 card that the T1 port will be assigned to. The T1 card types and their part numbers are shown in Table B-4.
    3. If the T1 card that will be used in this procedure is an HC-MIM or an E5-E1T1 card, continue the procedure by performing one of these steps.
      • If T1 cards are shown in 1 that are on the same shelf as the card that will contain the T1 port that is being added, and these cards have T1 ports 3 through 8 provisioned, contain channel bridged T1 ports, or unchannelized T1 ports, continue the procedure with 7 to add the T1 port with the parameters allowed for an HC-MIM or an E5-E1T1 card.
      • If no T1 cards, shown in 1, are not on the same shelf as the card that will contain the T1 port that is being added, continue the procedure with 3.
      • If T1 cards are shown in 1 that are on the same shelf as the card that will contain the T1 port that is being added, and these cards do not have T1 ports 3 through 8 provisioned, do not contain channel bridged T1 ports, or do not have unchannelized T1 ports, continue the procedure with 3.
  3. Verify that HIPR2 cards are installed in card locations 9 and 10 in the shelf containing the HC MIM or E5-E1T1 card that will contain the T1 port being added in this procedure by entering this command.

    rept-stat-gpl:gpl=hipr2

    This is an example of the possible output.

    rlghncxa03w 09-07-05 08:12:53 GMT  41.1.0
    GPL        CARD      RUNNING            APPROVED      TRIAL
    HIPR2      1109      126-002-000        126-002-000   126-003-000
    HIPR2      1110      126-002-000        126-002-000   126-003-000
    HIPR2      1209      126-002-000        126-002-000   126-003-000
    HIPR2      1210      126-002-000        126-002-000   126-003-000
    HIPR2      1309      126-002-000        126-002-000   126-003-000
    HIPR2      1310      126-002-000        126-002-000   126-003-000
    HIPR2      2109      126-002-000        126-002-000   126-003-000
    HIPR2      2110      126-002-000        126-002-000   126-003-000
    Command Completed
    
    If HIPR2 cards are installed in the shelf containing the HC MIM or E5-E1T1 card, continue the procedure by performing one of these steps.
    • If the card is an E5-E1T1 card, continue the procedure with 7.
    • If the card is an HC MIM, continue the procedure with 4.
    If HIPR2 cards are not installed on the shelf containing the HC MIM or E5-E1T1 card, go to Installation User's Guide and install the HIPR2 cards. Once the HIPR2 cards have been installed, continue the procedure by performing one of these steps.
    • If the card is an E5-E1T1 card, continue the procedure with 7.
    • If the card is an HC MIM, continue the procedure with 4.
  4. Verify whether or not that the Fan feature is on, by entering the rtrv-feat command. If the Fan feature is on, the entry FAN = on appears in the rtrv-feat command output.

    Note:

    The rtrv-feat command output contains other fields that are not used by this procedure. If you wish to see all the fields displayed by the rtrv-feat command, see the rtrv-feat command description in Commands User's Guide.

    If the Fan feature is on, continue the procedure with 7.

    If the Fan feature is off, continue the procedure with 5.

  5. Turn the Fan feature on by entering this command.

    chg-feat:fan=on

    Note:

    Once the Fan feature is turned on with the chg-feat command, it cannot be turned off.

    The Fan feature must be purchased before you turn this feature on with the chg-feat command. If you are not sure if you have purchased the Fan feature, contact your Sales Representative or Account Representative.

  6. The shelf containing the HC-MIM being added in this procedure must have fans installed. Verify whether or not fans are installed on the shelf.

    If the fans are installed, continue the procedure with 7.

    If the fans are not installed on the shelf containing the HC-MIM, go to Installation User's Guide and install the fans. After the fans have been installed and tested, continue the procedure with 7.

  7. Add the new T1 interface information to the database using the ent-t1 command and the parameter combinations shown in Table B-8, based on the type of T1 card being used.

    Table B-8 T1 Interface Parameter Combinations

    HC-MIM or an E5-E1T1 Card without Channel Bridging

    Mandatory Parameters

    :loc=location of the T1 card

    :t1port=1, 2, 3, 4, 5, 6, 7, 8

    Optional Parameters

    :encode=ami, b8zs

    Default value = b8zs

    :framing=sf, esf

    Default value = sf

    :ll=0 - 655

    Default value = 133

    :t1tsel=line, external

    Default value = line

    Notes:

    1. Channel cards cannot be specified with the ent-t1 command.

    2. To configure the T1 port for master timing, use the t1tsel=external parameter.

    3. The linkclass=chan parameter configures a channelized T1 port. Specifying the linkclass=chan parameter in this procedure is unnecessary as this is the default value for the linkclass parameter.

    For this example, enter these commands.

    ent-t1:loc=1215:t1port=2:encode=b8zs:t1tsel=line:framing=sf:ll=100

  8. Verify the changes using the rtrv-t1 command specifying the card location and the t1port value specified in 7. For this example, enter this command.

    rtrv-t1:loc=1215:t1port=2

    rlghncxa03w 09-05-28 09:12:36 GMT EAGLE5 41.0.0
    
          T1                                               LINK    MINSU
    LOC   PORT   ENCODE  T1TSEL    FRAMING  LL   CHANBRDG  CLASS   RATE
    1215  2      B8ZS    LINE      SF       100  ------    CHAN    ----
    
    TS1  ------    TS9   ------    TS17  ------
    TS2  ------    TS10  ------    TS18  ------
    TS3  ------    TS11  ------    TS19  ------
    TS4  ------    TS12  ------    TS20  ------
    TS5  ------    TS13  ------    TS21  ------
    TS5  ------    TS14  ------    TS22  ------
    TS7  ------    TS15  ------    TS23  ------
    TS8  ------    TS16  ------    TS24  ------
    
    
  9. Back up the new changes using the chg-db:action=backup:dest=fixed command. These messages should appear, the active Maintenance and Administration Subsystem Processor (MASP) appears first.
    BACKUP (FIXED) : MASP A - Backup starts on active MASP.
    BACKUP (FIXED) : MASP A - Backup on active MASP to fixed disk complete.
    BACKUP (FIXED) : MASP A - Backup starts on standby MASP.
    BACKUP (FIXED) : MASP A - Backup on standby MASP to fixed disk complete.
    

Figure B-6 Adding Channelized and non-Channel Bridged T1 Ports



Sheet 1 of 7



Sheet 2 of 7



Sheet 3 of 7



Sheet 4 of 7



Sheet 5 of 7



Sheet 6 of 7



Sheet 7 of 7