This procedure is used to increase the number of PCT (point code and CIC translations) entries that are allowed in the EAGLE. The EAGLE can contain a maximum of 1000 PCT entries.
The enable-ctrl-feat
command enables the PCT quantity by specifying the part number for the PCT quantity and the PCT quantity’s feature access key with these parameters.
:fak
– The feature access key supplied by Oracle. The feature access key contains 13 alphanumeric characters and is not case sensitive. If you do not have the feature access key for the PCT quantity you wish to enable, contact your Oracle Sales Representative or Account Representative.
:partnum
– The Oracle-issued part number for the PCT quantity shown in Table 4-1.
Table 4-1 PCT Quantities and Part Numbers
Part Number | PCT Quantity |
---|---|
893037201 | 25 |
893037202 | 50 |
893037203 | 75 |
893037204 | 100 |
893037205 | 150 |
893037206 | 200 |
893037207 | 250 |
893037208 | 1000 |
The enable-ctrl-feat
command requires a valid serial number for the EAGLE to be configured in the database, and that this serial number is locked. This can be verified with the rtrv-serial-num
command. The EAGLE is shipped with a serial number in the database, but the serial number is not locked. The serial number can be changed, if necessary, and locked once the EAGLE is on-site, by using the ent-serial-num
command. The ent-serial-num
command uses these parameters.
:serial
– The serial number assigned to the EAGLE. The serial number is not case sensitive.
:lock
– Specifies whether or not the serial number is locked. This parameter has only one value, yes
, which locks the serial number. Once the serial number is locked, it cannot be changed.
Note:
To enter and lock the EAGLE’s serial number, theent-serial-num
command must be entered twice, once to add the correct serial number to the database with the serial
parameter, then again with the serial
and the lock=yes
parameters to lock the serial number. You should verify that the serial number in the database is correct before locking the serial number. The serial number can be found on a label affixed to the control shelf (shelf 1100).Once the PCT quantity is enabled with the enable-ctrl-feat
command, the PCT quantity is also turned on. The chg-ctrl-feat
command is not necessary to turn on the PCT quantity.
Figure 4-1 Changing the Point Code and CIC Translation Quantity
Sheet 1 of 2
Sheet 2 of 2