This procedure is used to increase the number of E5-ATM-Bs that can contain three signaling links. There is maximum of 250 E5-ATM-Bs that can contain three signaling links. The EAGLE contains a maximum of 250 card slots for signaling links.
Note:
As of Release 46.6, E5-ATM refers to the E5-ATM-B (P/N 870-2972-xx) card.The
enable-ctrl-feat
command
enables the Three Links per E5-ATM Card quantity, in groups of 5 E5-ATMs, by
specifying the part number for the 3 Links per E5-ATM Card quantity and the
Three Links per E5-ATM Card quantity’s feature access key with these
parameters:
:fak
– The feature access key
supplied by Oracle. The feature access key contains 13 alphanumeric characters
and is not case sensitive. If you do not have the feature access key for the
Three Links per E5-ATM Card quantity you wish to enable, contact your Oracle
Sales Representative or Account Representative.
:partnum
– The Oracle-issued
part number for the Three Links per E5-ATM Card quantity shown in
Table C-11.
Table C-11 3 Links per E5-ATM-B Card Quantities and Part Numbers
Part Number | 3 Links per E5-ATM Card Quantity | Part Number | 3 Links per E5-ATM Card Quantity |
---|---|---|---|
893039101 | 5 | 893039126 | 130 |
893039102 | 10 | 893039127 | 135 |
893039103 | 15 | 893039128 | 140 |
893039104 | 20 | 893039129 | 145 |
893039105 | 25 | 893039130 | 150 |
893039106 | 30 | 893039131 | 155 |
893039107 | 35 | 893039132 | 160 |
893039108 | 40 | 893039133 | 165 |
893039109 | 45 | 893039134 | 170 |
893039110 | 50 | 893039135 | 175 |
893039111 | 55 | 893039136 | 180 |
893039112 | 60 | 893039137 | 185 |
893039113 | 65 | 893039138 | 190 |
893039114 | 70 | 893039139 | 195 |
893039115 | 75 | 893039140 | 200 |
893039116 | 80 | 893039141 | 205 |
893039117 | 85 | 893039142 | 210 |
893039118 | 90 | 893039143 | 215 |
893039119 | 95 | 893039144 | 220 |
893039120 | 100 | 893039145 | 225 |
893039121 | 105 | 893039146 | 230 |
893039122 | 110 | 893039147 | 235 |
893039123 | 115 | 893039148 | 240 |
893039124 | 120 | 893039149 | 245 |
893039125 | 125 | 893039150 | 250 |
The
enable-ctrl-feat
command
requires a valid serial number for the EAGLE to be configured in the database,
and that this serial number is locked. This can be verified with the
rtrv-serial-num
command. The
EAGLE is shipped with a serial number in the database, but the serial number is
not locked. The serial number can be changed, if necessary, and locked once the
EAGLE is on-site, by using the
ent-serial-num
command. The
ent-serial-num
command uses
these parameters.
:serial
– The serial number
assigned to the EAGLE. The serial number is not case sensitive.
:lock
– Specifies whether or
not the serial number is locked. This parameter has only one value,
yes
, which locks the serial
number. Once the serial number is locked, it cannot be changed.
Note:
To enter and lock the EAGLE’s serial number, theent-serial-num
command must be
entered twice, once to add the correct serial number to the database with the
serial
parameter, then again
with the
serial
and the
lock=yes
parameters to lock the
serial number. You should verify that the serial number in the database is
correct before locking the serial number. The serial number can be found on a
label affixed to the control shelf (shelf 1100).
Once the proxy point code quantity is
enabled with the
enable-ctrl-feat
command, the
proxy point code is also turned on. The
chg-ctrl-feat
command is not
necessary to turn on the proxy point code quantity.
A 3 Links per E5-ATM quantity cannot be enabled for the first time if there are any ATM high-speed signaling links in the database whose VCI value is greater than 16383. These signaling links must be removed by performing the Removing an SS7 Signaling Link procedure. These signaling links can be added back to the database by performing the Adding an ATM High-Speed Signaling Link procedure. The VCI value for these signaling links must be 16383 or less. If a 3 Links per E5-ATM quantity is being increased from a currently enabled 3 Links per E5-ATM quantity, then there are no ATM high-speed signaling links in the database whose VCI value is greater than 16383.